Schneider Electric LV848498WW — Circuit Breaker Accessories

LV848498WW MicroLogic 2.0 Xi Control Unit, MasterPacT, 690 V

MPNLV848498WW
Obsolete

Schneider Electric MasterPacT series, MicroLogic 2.0 Xi electronic control unit, LI protection, 690 V AC, drawout mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LV848498WW — Identification
ParameterValue
Product / component typeControl unit
Product rangeMasterPacT
Device applicationEquipment protection, monitoring and control
LV848498WW — Electrical
ParameterValue
Network type (AC/DC)AC
Rated operational voltage [Ue]690 V AC, +/- 10 %
Network frequency50/60 Hz
LV848498WW — Protection & Performance
ParameterValue
Trip unit technologyElectronic
Trip unit rating400 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A
Protection typeOverload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50
LV848498WW — Mechanical
ParameterValue
Device short nameMicroLogic 2.0 Xi
Control typeWired control
Mounting modeDrawout
LV848498WW — Environmental
ParameterValue
Pollution degree3 conforming to IEC 60947-1
Operating ambient air temperature-25...70 °C (operating) -35 °C (for start-up of product)
LV848498WW — Approvals
ParameterValue
StandardsEN/IEC 60947-2 EN/IEC 60092-202 EN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 61010-1

Product details

The LV848498WW is a Schneider Electric MicroLogic 2.0 Xi electronic control unit for MasterPacT air circuit breakers. It is a wired-control device with an LCD display (128 x 96 pixels) and provides equipment protection, monitoring, and control for distribution networks at 50/60 Hz. The trip unit offers LI protection — long-time overload (ANSI 49) and instantaneous short-circuit (ANSI 50) — with adjustable long-time delay in 0.5 s steps and electronic thermal memory. It is rated for operational voltages up to 690 V AC (+/- 10 %).

Fit and mounting — what the drawout form factor means for your panel

This control unit is a drawout-mounted module, meaning it plugs into the MasterPacT breaker cradle and can be removed without disturbing the main power wiring — useful for panel access, retrofit, or swap-out during a line changeover. Pole configurations supported are 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, and 4P 3d + OSN, with neutral protection settings selectable per the configuration. Trip unit ratings cover a wide band from 400 A through 6300 A, so the same control unit board can serve multiple breaker frame sizes with the appropriate sensor.

The LV848498WW integrates a power meter measuring current (I1, I2, I3, Iavg, IN RMS, Ig RMS), voltage (phase-to-phase and phase-to-neutral), active/reactive/apparent power and energy, power factor, frequency, THD, and unbalance. Accuracy is Class 0.5 for voltage unbalance, Class 1 for active energy, and Class 2 for THD(V). For MTZ1 frames, current accuracy is +/- 0.5 % from 40 to 1600 x 1.2 A. Measurement voltage range is 208...828 V AC phase-to-phase, 120...480 V AC phase-to-neutral, with a frequency measurement range of 40...70 Hz. The measurement category is IV per IEC 61010-2-30, suitable for utility-side metering at the service entrance.

Compliance and environmental — what documentation supports qualification

The control unit complies with EN/IEC 60947-2 (circuit-breakers), EN/IEC 60092-202 (marine), EN/IEC 60947-1, EN/IEC 60255-1 (measuring relays), and EN/IEC 61010-1 (safety). EMC immunity covers electrostatic discharge, electromagnetic fields, fast transients, surge (1.2/50 µs), conducted RF, and conducted/radiated emissions Class A per CISPR 22. Overvoltage category IV per IEC 61010-1. Relative humidity rating is 95 % at 55 °C per IEC 60068-2-30. Operating altitude is up to 5000 m with voltage derating to 560 V AC. Note: the unit is not approved for wet locations per IEC 61010-1.

Frequently asked questions

What is LV848498WW's listed poles (4P 3P) on this component line?

The control unit supports 4P and 3P configurations, with protected pole options including 3P 3d, 4P 3d, 4P 3d + N/2, 4P 4d, and 4P 3d + OSN.

What is LV848498WW's listed range (MasterPacT) on this component line?

The range is MasterPacT, Schneider Electric's family of air circuit breakers for distribution and generator protection.