Skip to main content
Schneider Electric LX0FH056 — Contactor & Starter Coils

TeSys LX0FH056 Contactor Coil, 110 V DC, Low Consumption

MPNLX0FH056
Active

TeSys F, contactor coil, LX0FH056, 110 V DC low consumption.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LX0FH056 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX0FH

Electrical

LX0FH056 — Electrical
ParameterValue
Control circuit voltage [Uc]110 V DC
Control circuit typeDC low consumption
Control circuit voltage limitsLatching: 0.85...1.1 Uc Unlatching: 0.85...1.1 Uc
Coil resistance (avg.)25 Ohm latching at 20 °C 364.61 Ohm unlatching at 20 °C

Performance & Durability

LX0FH056 — Performance & Durability
ParameterValue
Operating time50...100 ms unlatching 45...50 ms latching
Max. operating rate120 cyc/h 40 °C
Mechanical durability1 Mcycles

Product details

The LX0FH056 is a DC low-consumption contactor coil from the TeSys F range, designed to replace or populate the coil on a TeSys F contactor frame. It runs on 110 V DC control voltage, with latching and unlatching voltage limits of 0.85...1.1 Uc — meaning the coil holds in reliably down to about 93.5 V DC and picks up at the same threshold, so a sagging DC bus won't drop it prematurely. Operating time is 50...100 ms for unlatching and 45...50 ms for latching — a tight window that matters when the contactor is part of a sequenced start or safety circuit where timing coordination with other devices is critical. The coil resistance at 20 °C is 25 Ω latching and 364.61 Ω unlatching; that difference is normal for a DC economizer circuit that cuts power after pickup to reduce holding losses. Rated for 1 Mcycles mechanical durability and a maximum operating rate of 120 cycles per hour at 40 °C, so it handles frequent cycling in a conveyor or packaging line without derating. The DC low-consumption design keeps the control transformer and wiring smaller than a standard DC coil would demand.

Mounts directly onto the TeSys F contactor base; no adapter or bracket required. The DC low-consumption circuit means the coil draw is low enough that a 24 V DC supply with a DC-DC boost converter or a dedicated 110 V DC supply can feed it without oversizing. Keep the wiring run short — the 364.61 Ω unlatching resistance limits inrush, but long cable runs add capacitance that can cause false pickup on a noisy DC rail.

Frequently asked questions

What is the operating time of this coil?

Unlatching time is 50...100 ms; latching time is 45...50 ms. The spread on unlatching accounts for coil temperature and control voltage tolerance at the moment of dropout.

What control voltage does the LX0FH056 need?

110 V DC nominal, with latching and unlatching limits of 0.85...1.1 Uc (93.5 to 121 V DC). It is a DC low-consumption design, so it draws less steady-state current than a standard DC coil after pickup.

MPN
LX0FH056