Schneider Electric LX1FG140 — Contactor & Starter Coils

Schneider LX1FG140 TeSys F Contactor Coil, 140 V AC 50 Hz

MPNLX1FG140
Obsolete

Schneider Electric TeSys F series, LX1FG140, contactor coil, 140 V AC 50 Hz, 805 VA inrush, 55 VA hold.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FG140 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FG
Coil technologyWithout built-in suppressor module
LX1FG140 — Electrical
ParameterValue
Control circuit voltage [Uc]140 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)6.67 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)1.05 H
LX1FG140 — Power & Thermal
ParameterValue
Inrush power (VA)805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation18...24 W 50 Hz
LX1FG140 — Performance & Durability
ParameterValue
Operating time20...35 ms closing 7...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FG140 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX1FG140 is a replacement contactor coil from the TeSys F range, designed for 140 V AC 50 Hz control circuits. It pulls 805 VA inrush and holds at 55 VA, both at 50 Hz with a cos phi of 0.3. The coil has no built-in suppressor module, so you'll need to add one externally if your circuit requires it.

Closing time runs 20 to 35 ms, opening 7 to 15 ms — fast enough for standard motor starting but not for high-speed reversing applications where you'd want a DC coil. The coil dissipates 18 to 24 W at 50 Hz, which matters for panel heat buildup if you're grouping several contactors in a small enclosure. That's about 40 operations a minute — fine for a conveyor or pump cycle, but you'll hit the thermal limit if you're trying to jog a motor faster than that. The coil resistance is 6.67 ohms at 20 °C, and the closed-circuit inductance is 1.05 H. Drop-out voltage is 0.35 to 0.55 Uc at 55 °C, meaning the contactor will drop out somewhere between 49 and 77 V AC — useful to know if you're on a long cable run with voltage drop.

Deployment context

This coil snaps into a TeSys F contactor frame on a DIN rail. The 140 V AC 50 Hz control voltage is common in European panel designs, but verify your control transformer taps — a 120 V tap won't hold this coil reliably at the low end of the operational range (0.85 Uc = 119 V).

Frequently asked questions

What is the control voltage and frequency for this coil?

140 V AC at 50 Hz. The operational voltage range is 0.85 to 1.1 Uc (119 to 154 V) at 55 °C, and drop-out is 0.35 to 0.55 Uc (49 to 77 V).

Does this coil include a built-in suppressor?

No, it's specified as 'without built-in suppressor module'. You'll need to add an external RC snubber or varistor across the coil if your circuit requires suppression.

What is the heat dissipation of this coil?

18 to 24 W at 50 Hz. Factor that into your panel thermal calculation if multiple contactors are grouped together.