Skip to main content
Schneider Electric LX1FG660 — Contactor & Starter Coils

TeSys LX1FG660 Contactor Coil, 660-690V AC 50Hz, Obsolete

MPNLX1FG660
Obsolete

TeSys F, contactor coil, LX1FG660, 660...690 V AC 50 Hz, 805 VA inrush, 55 VA hold-in, 18...24 W heat dissipation.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX1FG660 — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1FG
Coil technologyWithout built-in suppressor module
LX1FG660 — Electrical
ParameterValue
Control circuit voltage [Uc]660...690 V AC 50 Hz
Control circuit typeAC 50 Hz
Control circuit voltage limitsDrop-out 0.35...0.55 Uc 50/60 Hz 131 °F (55 °C)) Operational 0.85...1.1 Uc 50/60 Hz 131 °F (55 °C))
Coil resistance (avg.)154 Ohm 68 °F (20 °C)
Coil inductance (closed circuit)21.8 H
LX1FG660 — Power & Thermal
ParameterValue
Inrush power (VA)805 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Hold-in power (VA)55 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation18...24 W 50 Hz
LX1FG660 — Performance & Durability
ParameterValue
Operating time20...35 ms closing 7...15 ms opening
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX1FG660 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Part Identity and Sourcing Status

The LX1FG660 lifecycle status is Obsolete.

Electrical and Mechanical Specifications

The coil operates on a 660...690 V AC 50 Hz control circuit, with an inrush power consumption of 805 VA at 50 Hz (cos φ 0.3) and a hold-in consumption of 55 VA at 50 Hz (cos φ 0.3). Heat dissipation is rated at 18...24 W at 50 Hz. The average resistance measures 154 Ω at 68 °F (20 °C), and the inductance of the closed circuit is 21.8 H. Operating time is specified as 20...35 ms for closing and 7...15 ms for opening. The control circuit voltage limits are: dropout at 0.35...0.55 Uc and operational at 0.85...1.1 Uc, both at 50/60 Hz and 131 °F (55 °C). The coil is supplied without a built-in suppressor module, which means the integrator must add external suppression (e.g., RC snubber or varistor) across the coil terminals to limit switching transients — a standard requirement for inductive loads in control panels.

This coil is a service part for TeSys F contactors — it mounts onto the contactor's magnet assembly and is wired to the control circuit via the coil terminals. Given the 660...690 V AC control voltage, this coil is suited for applications where the control supply is derived from a higher-voltage line, such as in heavy industrial installations with 690 V distribution. The absence of a built-in suppressor means the installer must verify that the control circuit's switching device (PLC output, relay, or contactor auxiliary) is rated for the coil's inrush current of 805 VA.

Frequently asked questions

What is LX1FG660's listed range (TeSys) on this component line?

The LX1FG660 belongs to the TeSys range, specifically the TeSys F series of contactor coils.

What is LX1FG660's listed category (18401-WORLD SERVICE PARTS(CTR ACCESS)) on this component line?

The category is 18401-WORLD SERVICE PARTS(CTR ACCESS), indicating it is classified as a service part for contactor accessories in the global service parts catalog.

MPN