TeSys LX1FG660 Contactor Coil, 660-690V AC 50Hz, Obsolete

MPN LX1FG660
Obsolete

TeSys F, contactor coil, LX1FG660, 660...690 V AC 50 Hz, 805 VA inrush, 55 VA hold-in, 18...24 W heat dissipation.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

LX1FG660 specifications
ParameterValue
Control circuit typeAC 50 Hz
Main product or component typeContactor coil
Coil voltage660...690 V AC 50 Hz
Temp operating max55 °C
Temp operating min-5 °C
Mechanical life cycles10 Mcycles
Operating time20...35 ms closing 7...15 ms opening
Operating temperature23...131 °F (-5...55 °C)

Product details

Part Identity and Sourcing Status

The LX1FG660 lifecycle status is Obsolete.

Electrical and Mechanical Specifications

The coil operates on a 660...690 V AC 50 Hz control circuit, with an inrush power consumption of 805 VA at 50 Hz (cos φ 0.3) and a hold-in consumption of 55 VA at 50 Hz (cos φ 0.3). Heat dissipation is rated at 18...24 W at 50 Hz. The average resistance measures 154 Ω at 68 °F (20 °C), and the inductance of the closed circuit is 21.8 H. Operating time is specified as 20...35 ms for closing and 7...15 ms for opening. The control circuit voltage limits are: dropout at 0.35...0.55 Uc and operational at 0.85...1.1 Uc, both at 50/60 Hz and 131 °F (55 °C). The coil is supplied without a built-in suppressor module, which means the integrator must add external suppression (e.g., RC snubber or varistor) across the coil terminals to limit switching transients — a standard requirement for inductive loads in control panels.

This coil is a service part for TeSys F contactors — it mounts onto the contactor's magnet assembly and is wired to the control circuit via the coil terminals. Given the 660...690 V AC control voltage, this coil is suited for applications where the control supply is derived from a higher-voltage line, such as in heavy industrial installations with 690 V distribution. The absence of a built-in suppressor means the installer must verify that the control circuit's switching device (PLC output, relay, or contactor auxiliary) is rated for the coil's inrush current of 805 VA.

MPN