Skip to main content
Schneider Electric LX1G3QLSEN — Contactor & Starter Coils

Schneider LX1G3QLSEN TeSys Giga Contactor Coil

MPNLX1G3QLSEN
Active

Schneider Electric TeSys Giga LX1G3QLSEN contactor coil, 200-500 V AC/DC 50/60 Hz, for LC1G115-225/3P standard contactors, built-in bidirectional peak limiting, push-in terminals, IP20.

$280.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX1G3QLSEN — Identification
ParameterValue
Product typeContactor coil
Product rangeTeSys
Device short nameLX1G
Coil technologyBuilt-in bidirectional peak limiting
LX1G3QLSEN — Electrical
ParameterValue
Control circuit voltage [Uc]200...500 V AC/DC 50/60 Hz
Control circuit voltage limitsOperational 0.8...1.1 Uc 140 °F (60 °C)) Drop-out 0...0.45 Uc 140 °F (60 °C))
LX1G3QLSEN — Power & Thermal
ParameterValue
Inrush power (VA)295 VA
Inrush power (W)215 W
Hold-in power (VA)13 VA
Hold-in power (W)8 W
LX1G3QLSEN — Performance & Durability
ParameterValue
Operating time20...35 ms opening 40...55 ms closing
Max. operating rate600 cyc/mn 140 °F (60 °C)
Mechanical durability5 Mcycles
LX1G3QLSEN — Environmental
ParameterValue
Operating temperature-13...140 °F (-25...60 °C)
IP ratingIP20 IEC 60529
Permissible ambient temperature-40...158 °F (-40...70 °C) at Uc
Storage temperature-76...176 °F (-60...80 °C)
Operating altitude9842.52 ft (3000 m) without derating 5000 m with derating factor
Pollution degree3 IEC 60947-1
LX1G3QLSEN — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 UL 60947-4-1A CSA C22.2 No 60947-4-1
Electromagnetic compatibility (EMC)EMC immunity conforming to IEC 60947-4-1 Emission tests criteria A conforming to IEC 60947-4-1 Immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to SEMI F47
LX1G3QLSEN — Mechanical
ParameterValue
Poles3P
Terminal connectionsControl circuit push-in termination 1 0.0003...0.004 in² (0.2...2.5 mm²) solid stranded without cable end sleeve AWG 26...AWG 12 Control circuit push-in termination 1 0.0004...0.004 in² (0.25...2.5 mm²) flexible with cable end sleeve AWG 24...AWG 14 Control circuit push-in termination 2 0.0008...0.002 in² (0.5...1.0 mm²) rigid or stranded with cable end sleeve AWG 20...AWG 18
Depth3.7 in (94.0 mm)
Width4.2 in (105.7 mm)
Height5.7 in (144.5 mm)

Product details

What this coil fits and why the voltage range matters

The LX1G3QLSEN is the control coil for Schneider Electric's TeSys Giga series, specifically the LC1G115 through LC1G225 three-pole standard contactors. It accepts 200...500 V AC/DC at 50/60 Hz, so it covers both 240 V and 480 V control circuits common in North American panels without needing a separate transformer tap. The built-in bidirectional peak limiting coil technology suppresses inrush spikes — 215 W / 295 VA inrush drops to 8 W / 13 VA holding. That matters for PLC output card sizing: the holding draw is low enough to run multiple coils off a single 24 VDC supply without exceeding the card's per-channel current limit.

Panel fit and wiring — push-in terminals save time

Dimensions are 5.7 in high by 4.2 in wide by 3.7 in deep (144.5 x 105.7 x 94.0 mm). The coil clips onto the contactor base; no extra DIN rail space is consumed beyond the contactor's own footprint. Control circuit push-in terminals accept solid or stranded wire from AWG 26 to AWG 12, or flexible with ferrule from AWG 24 to AWG 14. No screwdriver needed for termination — strip, push, done. That shanks a few minutes per panel when you're wiring a dozen starters.

Environmental and compliance — what the ratings actually mean

Rated pollution degree 3 per IEC 60947-1, meaning it tolerates conductive dust and condensation typical in unsealed industrial enclosures. IP20 finger-safe housing keeps live terminals out of reach behind the panel door. Operating temperature range -13 to 140 °F (-25 to 60 °C) with storage from -76 to 176 °F. At altitudes up to 3000 m no derating is needed; above that, up to 5000 m, apply the derating factor from the datasheet. Certified to EN/IEC 60947-4-1, UL 60947-4-1A, and CSA C22.2 No 60947-4-1 — the three standards that govern contactor and starter coordination. EMC immunity meets IEC 60947-4-1 criteria A and SEMI F47 voltage dip immunity, which is relevant for semiconductor fab tool power quality requirements.

Lifecycle and sourcing — active production, quoted to order

Sourced through authorized distribution channels against your BOM quantity.

Frequently asked questions

What contactors does LX1G3QLSEN fit?

It is the control coil for TeSys Giga LC1G115 through LC1G225 three-pole standard contactors. The 200-500 V AC/DC coil voltage covers both 240 V and 480 V control circuits.

What compliance documentation does Schneider Electric provide for LX1G3QLSEN?

The coil carries UL 60947-4-1A, CSA C22.2 No 60947-4-1, and EN/IEC 60947-4-1 certifications. EMC immunity meets IEC 60947-4-1 criteria A and SEMI F47 voltage dip immunity standards.

MPN
LX1G3QLSEN