Schneider Electric LX1LB150 — Contactor & Starter Coils

TeSys LX1LB150 replacement coil, 150 V AC 50 Hz

MPNLX1LB150
Active

Schneider Electric TeSys LX1 series replacement coil, LX1LB150, 150 V AC 50 Hz, 207.57 Ohm, 75 VA inrush / 8 VA sealed.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX1LB150 — Identification
ParameterValue
Product typeCoil
Product rangeTeSys
Device short nameLX1
LX1LB150 — Electrical
ParameterValue
Control circuit voltage [Uc]150 V AC 50 Hz
Coil resistance (avg.)207.57 Ohm at 68 °F (20 °C) +/- 10 %
Coil inductance6.6 H
LX1LB150 — Power & Thermal
ParameterValue
Power consumption (VA)75 VA AC 0.55 50 Hz inrush 8 VA AC 0.28 50 Hz sealed

Product details

The LX1LB150 is a replacement coil from the Schneider Electric TeSys range, designed to fit LX1 series contactors and control relays. It is a service part — the coil itself, not a complete contactor — intended for field replacement when the original coil fails or a different control voltage is needed. Rated for 150 V AC at 50 Hz control circuits, it draws 75 VA inrush at 0.55 power factor and settles to 8 VA sealed at 0.28 power factor. The average DC resistance measures 207.57 Ohm at 20 °C, within a ±10 % tolerance. Inductance is 6.6 H.

The 150 V AC 50 Hz rating is the control voltage the coil is wound for — apply that across the terminals and the magnetic circuit pulls in the contactor armature. The inrush figure (75 VA) is what the control transformer or PLC output must deliver momentarily; the sealed figure (8 VA) is the holding power after the contactor closes. A control transformer sized for the inrush peak avoids voltage sag that could prevent full pick-up. The 207.57 Ohm resistance at 20 °C is the coil winding's DC value, useful for verifying the coil with an ohmmeter before installation — a short or open winding reads well outside the ±10 % band. The 6.6 H inductance matters for suppression circuit design: a standard RC snubber across the coil contacts should be selected for this inductance to avoid excessive voltage spikes on dropout.

Frequently asked questions

What control voltage does the LX1LB150 coil require?

The coil is rated for 150 V AC at 50 Hz. It is not rated for DC or 60 Hz operation — verify your control circuit voltage matches this exactly.

What are the inrush and sealed power consumption of this coil?

Inrush is 75 VA at 0.55 power factor; sealed (holding) power is 8 VA at 0.28 power factor. The control transformer must be sized to handle the inrush peak without significant voltage drop.

How do I verify the coil is good before installing it?

Measure the DC resistance across the coil terminals. It should read 207.57 Ohm ±10 % at 20 °C ambient. A reading outside that band — especially a short (near 0 Ohm) or open (infinite) — indicates a damaged coil.

MPN
LX1LB150