Skip to main content
Schneider Electric LX9FF065 — Contactor & Starter Coils

Schneider LX9FF065 TeSys F Contactor Coil, 65 VAC, Obsolete

MPNLX9FF065
Obsolete

Schneider Electric TeSys F series, LX9FF065, specific contactor coil, 65 V AC 40-400 Hz low consumption, obsolete status.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FF065 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FF
Coil technologyWithout built-in suppressor module
LX9FF065 — Electrical
ParameterValue
Control circuit voltage [Uc]65 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)4.93 Ohm inrush 68 °F (20 °C) 152.2 Ohm holding 68 °F (20 °C)
LX9FF065 — Power & Thermal
ParameterValue
Inrush power (VA)690...855 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)6.6...8.1 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation5.9...7.2 W
LX9FF065 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FF065 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FF065 is a specific replacement coil for the TeSys F contactor range, wound for 65 V AC 40-400 Hz control circuits. It's a low-consumption design — inrush pulls 690-855 VA at 20 °C, then drops to 6.6-8.1 VA holding, with coil resistance settling at 152.2 Ω once sealed. Opening time is 130 ms, closing 35 ms, which is standard for this frame size. This is the coil only — no built-in suppressor module, so you'll need to add a varistor or RC snubber across the terminals if driving it from a PLC output or solid-state relay. The heat dissipation runs 5.9-7.2 W, so check for adequate ventilation inside the enclosure if multiple contactors are ganged.

This part is marked obsolete by Schneider. That's a solid service life for a contactor coil — the obsolescence isn't driven by wear-out, just Schneider's platform migration.

The 65 V AC control voltage is the first thing to verify — this is not a 24 V or 110 V coil. It operates between 0.85 and 1.1 Uc (55.25-71.5 V AC) and drops out between 0.35 and 0.55 Uc (22.75-35.75 V AC). If your control transformer is putting out 48 V or 120 V, this coil won't pull in reliably or will burn up. The inrush VA figure (690-855 VA) matters for transformer sizing — a 100 VA control transformer won't handle the inrush of this coil plus others pulling in simultaneously.

Frequently asked questions

What is LX9FF065's listed range?

It belongs to the TeSys F range of contactors and accessories from Schneider Electric.

What is LX9FF065's category?

The category is 22341-CONTACTOR,D,K,&F ACCESS, which covers contactors and their accessories in the D, K, and F frame sizes.

MPN
LX9FF065