Schneider Electric LX9FG055 — Contactor & Starter Coils

TeSys LX9FG055 specific contactor coil, 55 V AC, obsolete

MPNLX9FG055
Obsolete

Schneider Electric TeSys F, specific contactor coil, LX9FG055, 55 V AC 40..400 Hz low consumption, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FG055 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FG
Coil technologyWithout built-in suppressor module
LX9FG055 — Electrical
ParameterValue
Control circuit voltage [Uc]55 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)2.8 Ohm inrush 68 °F (20 °C) 74.28 Ohm holding 68 °F (20 °C)
LX9FG055 — Power & Thermal
ParameterValue
Inrush power (VA)950...1180 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)8.9...10.9 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation8...9.8 W
LX9FG055 — Performance & Durability
ParameterValue
Operating time130 ms opening 35 ms closing
Max. operating rate2400 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FG055 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FG055 is a specific contactor coil from the Schneider Electric TeSys F range, designed as a replacement coil for TeSys F contactors. It operates on a 55 V AC control circuit at 40...400 Hz, with low-consumption coil technology — meaning it draws 950...1180 VA inrush and settles to 8.9...10.9 VA holding at 68 °F (20 °C). The coil dissipates 8...9.8 W of heat during continuous operation, which matters for enclosure thermal budgeting when replacing a failed coil in a panel.

Control circuit voltage limits are specified at 0.85...1.1 Uc for operational hold-in at 131 °F (55 °C), and drop-out occurs between 0.35...0.55 Uc at the same temperature. This means the coil reliably picks up when line voltage stays above 46.75 V AC and drops out cleanly below 19.25 to 30.25 V AC — important for brownout ride-through assessment on the control transformer. Operating time is 130 ms opening and 35 ms closing, which is standard for a contactor coil of this class. Ambient air temperature for operation spans -5...55 °C (23...131 °F), covering most indoor panel environments. The coil has no built-in suppressor module — if your control circuit requires flyback suppression (for PLC output or relay drive), you will need to add an external RC snubber or varistor across the coil terminals.

Frequently asked questions

What is the control voltage and frequency range for this coil?

The control circuit voltage is 55 V AC at 40...400 Hz. Operational hold-in range is 0.85...1.1 Uc (46.75...60.5 V AC) at 131 °F (55 °C), and drop-out occurs at 0.35...0.55 Uc (19.25...30.25 V AC).

What is the mechanical durability and maximum operating rate?

Mechanical durability is rated at 10 Mcycles. Maximum operating rate is 2400 cycles per hour at 131 °F (55 °C).

Does this coil include a built-in suppressor module?

No. The coil technology is listed as 'Without built-in suppressor module'. External suppression (RC snubber or varistor) must be added if the control circuit requires it.