Schneider Electric LX9FH0242 — Contactor & Starter Coils

TeSys LX9FH0242 Contactor Coil, 24 V AC, Obsolete

MPNLX9FH0242
Obsolete

TeSys F, specific contactor coil, 24 V AC 40...400 Hz low consumption, LX9FH0242.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LX9FH0242 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FH
Coil technologyWithout built-in suppressor module
LX9FH0242 — Electrical
ParameterValue
Control circuit voltage [Uc]24 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)0.84 Ohm inrush 68 °F (20 °C) 18.6 Ohm holding 68 °F (20 °C)
LX9FH0242 — Power & Thermal
ParameterValue
Inrush power (VA)560...660 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)8...10 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation8.4...10.4 W
LX9FH0242 — Performance & Durability
ParameterValue
Operating time25 ms opening 45 ms closing
Max. operating rate3600 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FH0242 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Part identity and fit

The LX9FH0242 is a specific contactor coil within the TeSys F range, designed as the replaceable solenoid for a TeSys F contactor frame. It is a 24 V AC coil rated for 40...400 Hz, low-consumption type, meaning it draws reduced hold-in power once the armature seats. This coil is not a standalone contactor — it is the magnetic actuator that mounts onto the contactor body. The operating time is 25 ms opening, 45 ms closing, which governs how fast the main poles break and make load current.

Coil electrical characteristics and suppression

Coil inrush power draws 560...660 VA at 68 °F (20 °C), dropping to 8...10 VA holding once the contactor is sealed. The average resistance is 0.84 Ω inrush and 18.6 Ω holding at the same temperature. Heat dissipation runs 8.4...10.4 W — that heat must be considered in a densely packed panel, particularly if the contactor cycles near its maximum rate of 3600 cycles per hour at 55 °C. This coil is supplied without a built-in suppressor module. An external RC snubber or varistor across the coil terminals is mandatory to limit back-EMF on the control circuit at dropout.

Schneider Electric has marked the LX9FH0242 as obsolete.

Mechanical durability and thermal limits

The ambient operating range is -5 to 55 °C; above that, coil temperature rise from the 8.4...10.4 W dissipation may exceed insulation class limits unless derated.

Frequently asked questions

What are the key electrical ratings of the LX9FH0242?

Control voltage is 24 V AC 40...400 Hz. Inrush power is 560...660 VA, holding power 8...10 VA. Coil resistance is 0.84 Ω inrush and 18.6 Ω holding at 20 °C. Heat dissipation is 8.4...10.4 W.

Does the LX9FH0242 include a built-in coil suppression module?

No. It is supplied without a built-in suppressor module. An external RC snubber or varistor must be added to protect the driving circuit from back-EMF.

MPN
LX9FH0242