Schneider Electric LX9FH0952 — Contactor & Starter Coils

TeSys LX9FH0952 contactor coil, 95 V AC 40-400 Hz

MPNLX9FH0952
Active

TeSys F specific contactor coil, 95 V AC 40..400 Hz low consumption, LX9FH0952.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LX9FH0952 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FH
Coil technologyWithout built-in suppressor module
LX9FH0952 — Electrical
ParameterValue
Control circuit voltage [Uc]95 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.35...0.55 Uc 131 °F (55 °C))
Coil resistance (avg.)12.18 Ohm inrush 68 °F (20 °C) 305 Ohm holding 68 °F (20 °C)
LX9FH0952 — Power & Thermal
ParameterValue
Inrush power (VA)560...660 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)8...10 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation8.4...10.4 W
LX9FH0952 — Performance & Durability
ParameterValue
Operating time25 ms opening 45 ms closing
Max. operating rate3600 cyc/h 131 °F (55 °C)
Mechanical durability10 Mcycles
LX9FH0952 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FH0952 is a specific contactor coil from the TeSys F range, designed as a replacement or spare coil for TeSys F contactors. It operates on a 95 V AC control circuit at 40 to 400 Hz, with low-consumption coil technology. This coil does not include a built-in suppressor module, so you will need to add an external RC snubber or varistor across the coil terminals if your application requires suppression of switching transients — common on PLC-driven or electronic control circuits.

The coil draws 560 to 660 VA inrush at 68 °F (20 °C) across the 40-400 Hz range, dropping to 8 to 10 VA holding. That inrush figure tells you the momentary load on your control transformer when the contactor pulls in — make sure your 95 V AC supply can deliver that surge without dropping below the 0.85 Uc operational limit (80.75 V AC at 131 °F). Coil resistance measures 12.18 Ω inrush and 305 Ω holding at 68 °F (20 °C). The holding resistance is what determines steady-state current draw — roughly 0.31 A at 95 V AC — useful for sizing control circuit fusing. Heat dissipation runs 8.4 to 10.4 W. In a densely packed panel, that heat adds up; allow natural convection around the contactor or keep spacing per TeSys F guidelines. Opening time is 25 ms, closing time 45 ms. That 45 ms pull-in delay matters for sequencing logic — if you need faster response, this coil is not the pick.

Mechanical life and operating rate

That is one cycle per second — fine for most motor starting and general switching, but not for high-speed applications like rapid reversing or jogging duty.

Frequently asked questions

What is the control voltage for LX9FH0952?

95 V AC at 40 to 400 Hz, low-consumption type. Operational limits are 0.85 to 1.1 Uc (80.75 to 104.5 V AC at 131 °F); dropout occurs between 0.35 and 0.55 Uc (33.25 to 52.25 V AC).

Does this coil include a built-in suppressor?

No, the coil technology is listed as 'without built-in suppressor module'. You will need to add an external RC snubber or varistor if your control circuit requires transient suppression.

What is the inrush and holding VA for this coil?

Inrush is 560 to 660 VA at 68 °F (20 °C) across the 40-400 Hz range. Holding power consumption is 8 to 10 VA at the same conditions.