Schneider LX9FJ912 TeSys F Contactor Coil, 24 VDC / 27-29 VA

MPNLX9FJ912
Obsolete

Schneider Electric TeSys F, specific contactor coil LX9FJ912, 24 V DC / 27...29 V AC 40-400 Hz control circuit, 60 ms opening / 20 ms closing, 10 Mcycles mechanical durability.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LX9FJ912 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FJ
Coil technologyWithout built-in suppressor module
LX9FJ912 — Electrical
ParameterValue
Control circuit voltage [Uc]24 V DC 27...29 V AC 40...400 Hz
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
LX9FJ912 — Power & Thermal
ParameterValue
Inrush power (VA)500 VA 40...400 Hz (at 68 °F (20 °C))
Hold-in power (VA)23 VA 40...400 Hz (at 68 °F (20 °C))
Heat dissipation11.4...13.9 W
LX9FJ912 — Performance & Durability
ParameterValue
Operating time60 ms opening 20 ms closing
Max. operating rate3600 cyc/h 158 °F (70 °C)
Mechanical durability10 Mcycles
LX9FJ912 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FJ912 is a specific contactor coil from the Schneider TeSys F range, designed as the replaceable magnetic coil for TeSys F contactors. It operates the contactor's armature — 60 ms to open, 20 ms to close — which governs how fast the main poles make or break the load circuit. The control circuit accepts either 24 V DC or 27...29 V AC at 40...400 Hz, making it flexible for panels with mixed control voltages. Inrush power hits 500 VA at 20 °C; holding power drops to 23 VA once the armature seals. Heat dissipation runs 11.4 to 13.9 W, so the coil contributes noticeable thermal load inside the enclosure — factor that into cabinet sizing if multiple contactors are ganged. The coil lacks a built-in suppressor module, so you'll need an external RC snubber or varistor across the coil terminals if driving it from a PLC output or electronic timer.

This coil mounts directly onto the TeSys F contactor's magnet assembly — it is the replaceable element, not the full contactor. The control circuit voltage limits are 0.85...1.1 Uc for pickup at 55 °C, and dropout occurs between 0.3 and 0.5 Uc at the same temperature — useful to know when verifying hold-in on a brownout or long control-wire run.

Frequently asked questions

What is the closest alternative to the LX9FJ912?

No official successor order code is listed in the lifecycle record for this coil. For a pin-compatible or functional replacement, the best approach is to match the TeSys F contactor frame size and control voltage (24 V DC / 27-29 V AC) — the coil must be specific to the contactor's magnetic circuit. An RFQ can identify available cross-references or remaining stock.

What control voltages does the LX9FJ912 accept?

The coil accepts 24 V DC or 27...29 V AC at 40...400 Hz. The control circuit voltage limits for pickup are 0.85 to 1.1 times Uc at 55 °C, and dropout occurs between 0.3 and 0.5 times Uc at the same temperature.

Does the LX9FJ912 have a built-in coil suppression?

No, the coil technology is listed as 'without built-in suppressor module'. An external RC snubber or varistor must be added across the coil terminals when switching with solid-state outputs or electronic timers.