TeSys LX9FJ927 Contactor Coil, 125 V AC/DC, Obsolete

MPNLX9FJ927
Obsolete

TeSys F, specific contactor coil, LX9FJ927, 125 V DC low consumption, 125 V AC, 60 ms opening, 20 ms closing, 10 Mcycles mechanical durability.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FJ927 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FJ
Coil technologyWithout built-in suppressor module
LX9FJ927 — Electrical
ParameterValue
Control circuit voltage [Uc]125 V DC 125 V AC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
Coil inductance (closed circuit)2 H
LX9FJ927 — Power & Thermal
ParameterValue
Inrush power (W)430 W 68 °F (20 °C))
Hold-in power (W)22 W 68 °F (20 °C)
Heat dissipation11.4...13.9 W
LX9FJ927 — Performance & Durability
ParameterValue
Operating time60 ms opening 20 ms closing
Max. operating rate3600 cyc/h 158 °F (70 °C)
Mechanical durability10 Mcycles
LX9FJ927 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

Part Identity and Key Specs

The LX9FJ927 is a specific contactor coil from the TeSys F range, designed for use with TeSys F contactors. It operates on a 125 V control circuit, accepting both AC (40...400 Hz) and DC low-consumption supply. Coil opening time is 60 ms, closing time is 20 ms — these switching speeds matter for coordinating with upstream protection and PLC scan cycles. Control voltage limits are operational 0.85...1.1 Uc at 131 °F (55 °C), with drop-out at 0.3...0.5 Uc. This means the coil holds in reliably down to about 106 V on a 125 V nominal supply, and drops out cleanly below about 38 V — important for brownout ride-through and predictable de-energization.

Integration Notes for Panel Builders

This coil has no built-in suppressor module, so an external RC snubber or flyback diode must be added across the coil terminals when driven by a PLC output or solid-state relay. Without suppression, the inductive kick from the 2 H closed-circuit inductance can damage switching contacts or cause EMI issues on the control wiring. Heat dissipation runs 11.4...13.9 W during hold-in — enough to raise temperature inside a crowded enclosure. Allow adequate ventilation or derating when mounting multiple coils side-by-side in a panel. Maximum operating rate is 3600 cycles per hour at 158 °F (70 °C). For high-duty applications like rapid cycling conveyors or press controls, verify the duty cycle stays within this limit to avoid coil overheating.

Frequently asked questions

What is the control voltage for this coil?

The LX9FJ927 operates on 125 V control voltage, accepting both AC (40...400 Hz) and DC low-consumption supply.

What are the key timing specs for the LX9FJ927?

Opening time is 60 ms, closing time is 20 ms. Mechanical durability is rated at 10 million cycles.

Does this coil include a built-in suppressor?

No, the LX9FJ927 is supplied without a built-in suppressor module. An external snubber or flyback diode is required for inductive load switching.