Schneider LX9FL923 TeSys F Contactor Coil, 84-93 V DC, Obsol

MPNLX9FL923
Active

Schneider TeSys F specific contactor coil, LX9FL923, 84-93 V DC low consumption, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FL923 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FL
Coil technologyWithout built-in suppressor module
LX9FL923 — Electrical
ParameterValue
Control circuit voltage [Uc]84...93 V DC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
LX9FL923 — Power & Thermal
ParameterValue
Inrush power (W)733 W 68 °F (20 °C))
Hold-in power (W)48 W 68 °F (20 °C)
Heat dissipation22.8...27.8 W
LX9FL923 — Performance & Durability
ParameterValue
Operating time60 ms opening 20 ms closing
Max. operating rate1800 cyc/h 158 °F (70 °C)
Mechanical durability5 Mcycles
LX9FL923 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FL923 is a specific contactor coil from the Schneider TeSys F range, designed to operate a TeSys F contactor when energized at 84 to 93 V DC. It is a low-consumption coil, drawing 48 W hold-in power at 68 °F (20 °C) with an inrush of 733 W at the same temperature. The coil technology is without a built-in suppressor module, so you'll need to add external suppression if the control circuit demands it. The control circuit accepts AC 40 to 400 Hz or DC low-consumption drive. Opening time is 60 ms, closing time 20 ms. Ambient operating temperature range is 23 to 131 °F (-5 to 55 °C).

The 84 to 93 V DC control voltage is tight — operational limits are 0.85 to 1.1 Uc at 131 °F (55 °C), meaning the coil will pick up reliably between roughly 71 V and 102 V DC. Drop-out occurs between 0.3 and 0.5 Uc (about 25 to 46 V DC). If your control supply sags below that, the contactor drops out. This matters for DC control buses with long cable runs or shared loads. Heat dissipation runs 22.8 to 27.8 W continuous. In a densely packed panel, that adds up — ensure adequate ventilation or derating if mounted alongside other heat sources. The 5 Mcycles mechanical durability is typical for a contactor coil; the limiting factor in practice is often the contactor's electrical endurance under load, not the coil itself.

Frequently asked questions

What is the closest alternative to the LX9FL923?

No official successor order code is listed in the lifecycle record. Any replacement must be a TeSys F coil with the same mechanical mounting and a control voltage that falls within 84 to 93 V DC. You will need to verify the specific contactor frame and coil interface before substituting.

How do I source the LX9FL923 now that it is obsolete?

Source it to order against an RFQ through surplus or last-time-buy channels. We can quote you on available stock — buying ahead covers your BOM line for years, but the available inventory is finite.