TeSys LX9FL933 Contactor Coil, 264-299 V DC, Low Consumption

MPNLX9FL933
Active

TeSys F specific contactor coil, LX9FL933, 264..299 V DC low consumption, 48 W hold-in, 733 W inrush.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LX9FL933 — Identification
ParameterValue
Product typeSpecific contactor coil
Product rangeTeSys
Device short nameLX9FL
Coil technologyWithout built-in suppressor module
LX9FL933 — Electrical
ParameterValue
Control circuit voltage [Uc]264...299 V DC
Control circuit typeAC 40...400 Hz low consumption DC low consumption
Control circuit voltage limitsOperational 0.85...1.1 Uc 131 °F (55 °C)) Drop-out 0.3...0.5 Uc 131 °F (55 °C))
LX9FL933 — Power & Thermal
ParameterValue
Inrush power (W)733 W 68 °F (20 °C))
Hold-in power (W)48 W 68 °F (20 °C)
Heat dissipation22.8...27.8 W
LX9FL933 — Performance & Durability
ParameterValue
Operating time60 ms opening 20 ms closing
Max. operating rate1800 cyc/h 158 °F (70 °C)
Mechanical durability5 Mcycles
LX9FL933 — Environmental
ParameterValue
Operating temperature23...131 °F (-5...55 °C)

Product details

The LX9FL933 is a specific replacement coil for the TeSys F contactor range. It's the part that pulls the contactor in and holds it closed — no built-in suppressor, so you add the RC snubber or varistor externally based on your panel's noise environment. Rated for 264...299 V DC control voltage, with an operational range of 0.85...1.1 Uc at 131 °F (55 °C) and drop-out between 0.3...0.5 Uc. That means it'll hold in down to about 224 V DC and drop out cleanly between 79 and 132 V DC — useful to know if your DC bus sags under load. The coil draws 733 W inrush at 68 °F (20 °C) to pull the armature in, then settles to 48 W hold-in power. Heat dissipation runs 22.8...27.8 W once seated — that's the continuous thermal load the enclosure has to shed, so factor it into your panel's thermal budget.

Switching performance and duty cycle

Opening time is 60 ms, closing time is 20 ms. That's fast enough for most motor-start and isolation duties on a process line. Maximum operating rate is 1800 cycles per hour at 158 °F (70 °C) — about one cycle every two seconds, which covers high-speed indexing applications. Mechanical durability is rated at 5 million cycles. That's the mechanical life of the coil assembly itself — the contactor's electrical life will depend on the load it's switching (resistive vs motor), but the coil won't be the weak link in most installations.

Frequently asked questions

What is the control voltage range for LX9FL933?

Rated control voltage is 264...299 V DC. Operational limits are 0.85...1.1 Uc at 131 °F (55 °C), and drop-out is 0.3...0.5 Uc at the same temperature.

Does LX9FL933 include a built-in suppressor module?

No, it is specified as 'without built-in suppressor module'. You must add an external RC snubber or varistor across the coil terminals for transient suppression.

What is the heat dissipation of LX9FL933?

Heat dissipation is 22.8...27.8 W once the coil is held in. That's the continuous thermal load the enclosure must handle.

What is the mechanical durability of this coil?