Skip to main content
Schneider Electric MGN60866 — 1-Pole MCB (DIN Rail)

MGN60866 C60N MCB, 1P 6A C-curve, 10 kA, Multi9

MPNMGN60866
Obsolete

Schneider Electric Multi9 C60N, MGN60866, 1-pole 6 A miniature circuit breaker, C-curve, 10 kA breaking capacity at 240 V AC, 35 mm DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGN60866 — Identification
ParameterValue
Product nameC60
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60N
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN60866 — Electrical & Protection
ParameterValue
Rated current (In)6 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)240 V AC 50/60 Hz phase to neutral
Tripping curve codeC
Magnetic tripping limit8.5 x In +/- 20 %
Breaking capacity (Icu / AIR)10 kA Icu at 240 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2 3 kA Icu at 415 V AC 50/60 Hz phase to neutral conforming to EN/IEC 60947-2
Network type (AC/DC)DC
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN60866 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminals1...25 mm² rigid Tunnel type terminals1...25 mm² flexible without cable end Tunnel type terminals1...25 mm² flexible with cable end
Mounting support35 mm symmetrical DIN rail
Mounting modeFixed
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)Power circuit: 2 N.m
MGN60866 — Environmental
ParameterValue
Operating ambient temperature-30...70 °C
Storage ambient temperature-40...80 °C
IP degree of protectionIP20 conforming to EN/IEC 60947-2
MGN60866 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2

Product details

The MGN60866 is a Schneider Electric C60N miniature circuit breaker from the Multi9 range, rated 6 A at 50 °C with a C-curve trip characteristic. The 10 kA Icu breaking capacity at 240 V AC phase-to-neutral (per EN/IEC 60947-2) covers most residential and light commercial fault levels; the 3 kA rating at 415 V AC is the ceiling for three-phase line-to-neutral faults.

The C-curve magnetic trip triggers at 8.5 x In ±20 %, so this 6 A breaker holds through motor inrush and capacitive loads that a B-curve would nuisance-trip on, but clears faster than a D-curve for general distribution.

Tightening torque for power circuit terminals is 2 N.m; strip length 14 mm. IP20 finger-safe terminals suit enclosed panels. Compatible with comb busbars and distribution blocks on top or bottom for multi-pole ganging.

Frequently asked questions

Where can I buy MGN60866 and how do I get a price?

The MGN60866 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is MGN60866's breaking capacity?

The MGN60866 has a breaking capacity of 10 kA Icu at 240 V AC 50/60 Hz phase-to-neutral, and 3 kA Icu at 415 V AC 50/60 Hz phase-to-neutral, both conforming to EN/IEC 60947-2.

What compliance documentation does MGN60866 carry?

The MGN60866 is certified to EN/IEC 60947-2, with pollution degree 3, IP20 protection, and suitability for isolation per that standard.

MPN