Skip to main content
Schneider Electric MGN61861 — 1-Pole MCB (DIN Rail)

MGN61861 Multi9 C60H-DC MCB, 1P, 4 A, Curve K, DC

MPNMGN61861
Obsolete

Schneider Electric Multi9 C60H-DC miniature circuit breaker, 1 pole, 4 A, curve K, 20 kA breaking capacity at 110 V DC, clip-on DIN rail mount, grey.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61861 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Product / component typeMiniature circuit-breaker
Product rangeMulti9
Device short nameC60H-DC
Poles description1P
Number of protected poles1
Device applicationDistribution
MGN61861 — Electrical & Protection
ParameterValue
Rated current (In)4 A at 50 °C conforming to EN/IEC 60947-2
Rated operational voltage (Ue)250 V DC 110 V DC 220 V DC
Tripping curve codeK
Magnetic tripping limit12 x In +/- 20 % DC
Breaking capacity (Icu / AIR)20 kA Icu at 110 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220 V DC conforming to EN/IEC 60947-2 6 kA Icu at 250 V DC conforming to EN/IEC 60947-2
Network type (AC/DC)DC
Trip unit technologyThermal-magnetic
Control / actuation typeToggle
Mechanical durability (cycles)20000 cycles
MGN61861 — Mounting & Connection
ParameterValue
Terminal connections / wire rangeTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Mounting supportDIN rail
Mounting modeClip-on
Width18 mm
Height81 mm
Depth73 mm
Tightening torque (by circuit)2.5 N.m top or bottom
MGN61861 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
MGN61861 — Approvals
ParameterValue
Conformity standardsEN/IEC 60947-2
MGN61861 — Electrical
ParameterValue
[Ui] rated insulation voltage500 V DC conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-2

Product details

It's rated 4 A at 50 °C (conforming to EN/IEC 60947-2) with a K-curve magnetic trip of 12 x In ±20 % DC. That curve means it's designed for DC loads with moderate inrush — think DC power supplies, control circuits, or DC distribution panels where you need a thermal-magnetic trip but don't want nuisance trips from a short capacitive charge. The breaking capacity steps are 20 kA at 110 V DC, 10 kA at 220 V DC, and 6 kA at 250 V DC — so at 110 V it handles a serious fault without upstream coordination worries. It's a category A breaker (no intentional short-time delay), suitable for isolation, and carries an IP20 finger-safe front with IP40 inside an enclosure.

Clip-on DIN rail mount, 18 mm wide (2 x 9 mm pitches), 81 mm tall, 73 mm deep. It's a single-module footprint — standard for a 1P MCB. Tunnel-type terminals top and bottom accept up to 25 mm² rigid stranded, or 16 mm² flexible, with a 14 mm strip length and 2.5 N·m torque. You can land up to three 1 mm² flexible conductors per terminal if you're daisy-chaining. Pollution degree 3 means it's rated for industrial environments with conductive pollution, and tropicalisation class 2 (per IEC 60068-2) handles humidity up to 95 % at 55 °C. The toggle gives clear ON/OFF indication, and the contact position indicator confirms isolation visually. Padlockable for lockout/tagout.

Frequently asked questions

Where can I buy MGN61861 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is the breaking capacity of MGN61861 at different DC voltages?

20 kA Icu at 110 V DC, 10 kA at 220 V DC, and 6 kA at 250 V DC, all conforming to EN/IEC 60947-2.

What does the K curve mean on this DC MCB?

The K curve has a magnetic tripping threshold of 12 x In ±20 % DC, designed for DC loads with moderate inrush such as DC power supplies and control circuits.

What compliance documentation does this brand provide for MGN61861?

The breaker conforms to EN/IEC 60947-2, with IP20/IP40 protection, pollution degree 3, and tropicalisation class 2 per IEC 60068-2. It is suitable for isolation per the same standard.

MPN
MGN61861