Skip to main content
Schneider Electric MGN61877 — 2-Pole MCB (DIN Rail)

MGN61877 Multi9 C60H-DC MCB, 2P 3A DC, 20 kA

MPNMGN61877
Obsolete

Schneider Electric Multi9 C60H-DC, MGN61877, 2-pole DC miniature circuit breaker, 3 A rated current, 20 kA breaking capacity at 250 V DC, clip-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

MGN61877 — Identification
ParameterValue
Product nameMulti9 C60H-DC
Series / familyMulti9
Device short nameC60H-DC
Product / component typeMiniature circuit-breaker
Device applicationDistribution
MGN61877 — Electrical
ParameterValue
Rated current [In]3 A at 50 °C conforming to EN/IEC 60947-2
Number of protected poles2
Pole configuration2P
Rated operational voltage [Ue]250 V DC 500 V DC 220 V DC 440 V DC
Network type (AC/DC)DC
MGN61877 — Protection
ParameterValue
Tripping curve codeK
Magnetic tripping limit12 x In +/- 20 % DC
Breaking capacity (Icu)20 kA Icu at 220 V DC conforming to EN/IEC 60947-2 20 kA Icu at 250 V DC conforming to EN/IEC 60947-2 10 kA Icu at 440 V DC conforming to EN/IEC 60947-2 6 kA Icu at 500 V DC conforming to EN/IEC 60947-2
Rated service breaking capacity [Ics]15 kA 75 % conforming to EN/IEC 60947-2 - 220 V DC 15 kA 75 % conforming to EN/IEC 60947-2 - 250 V DC 7.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V DC 4.5 kA 75 % conforming to EN/IEC 60947-2 - 500 V
Suitable for isolationYes conforming to EN/IEC 60947-2
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Operating / control typeToggle
Mechanical durability (cycles)20000 cycles
MGN61877 — Mechanical
ParameterValue
9 mm pitches4
Width36 mm
Height81 mm
Depth73 mm
Mounting supportDIN rail
Mounting modeClip-on
Terminal connectionsTunnel type terminal (top or bottom)1...25 mm² (AWG 18...AWG 4) - rigid stranded Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible Tunnel type terminal (top or bottom)1...16 mm² (AWG 18...AWG 6) - flexible with ferrule Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - rigid stranded Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible Tunnel type terminal (top or bottom) - 2 cable(s) 1...10 mm² (AWG 18...AWG 8) - flexible with ferrule Tunnel type terminal (top or bottom) - 3 cable(s) 1 mm² (AWG 18) - flexible stranded
Terminal tightening torque2.5 N.m top or bottom
Local signalling / indicationON/OFF indication
Contact position indicatorYes
MGN61877 — Environmental
ParameterValue
Operating temperature range-25...70 °C
Storage temperature range-40...85 °C
Relative humidity95 % at 55 °C
MGN61877 — Approvals
ParameterValue
Standards / complianceEN/IEC 60947-2

Product details

DC-rated miniature circuit breaker for 2-pole protection

The MGN61877 is a Schneider Electric Multi9 C60H-DC miniature circuit breaker — a 2-pole (2P) thermal-magnetic MCB rated at 3 A at 50 °C per EN/IEC 60947-2, designed specifically for DC networks. Its breaking capacity hits 20 kA Icu at 250 V DC and still delivers 10 kA at 440 V DC, so it handles fault currents across the common DC bus voltages found in industrial control panels, solar combiner boxes, and battery distribution.

Breaking capacity and selectivity in DC circuits

What sets this breaker apart from a standard AC-rated MCB is its DC-optimized arc extinction. The C60H-DC maintains 20 kA Icu at 220 V DC and 250 V DC, then steps down to 10 kA at 440 V DC and 6 kA at 500 V DC. That means on a 250 V DC bus — typical for telecom or UPS systems — it fully interrupts a 20 kA fault without cascading upstream. The magnetic trip threshold is fixed at 12 x In (±20 %), so it clears short-circuits fast while riding through moderate inrush.

Tightening torque is 2.5 N.m top or bottom. IP20 finger-safe on the front; IP40 inside the modular enclosure.

Frequently asked questions

How do I get current pricing and availability for MGN61877?

Submit an RFQ through this listing. Pricing and stock levels are confirmed at quote time — we source across independent distribution to match your required quantity and delivery window.

What is MGN61877's breaking capacity at different DC voltages?

The MGN61877 delivers 20 kA Icu at 220 V DC and 250 V DC, 10 kA at 440 V DC, and 6 kA at 500 V DC, all per EN/IEC 60947-2. This lets you coordinate downstream on a 250 V DC bus without stepping up to a larger frame.

What compliance standards does MGN61877 meet?

It is certified to EN/IEC 60947-2 for DC miniature circuit breakers, with pollution degree 3 and tropicalisation class 2 per IEC 60068-2. Isolation suitability is confirmed per the same standard.

MPN
MGN61877