Skip to main content
Schneider Electric TM241C24R

Modicon M241 TM241C24R Logic Controller, 24 I/O, Active

MPNTM241C24R
Active

Schneider Electric Modicon M241 logic controller, TM241C24R — 24 I/O, relay/transistor hybrid outputs, 4 fast HSC inputs at 200 kHz, CE/UL/CSA/IEC 61131-2.

$298.45 – $695.38Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

TM241C24R key specifications
ParameterValue
Battery typeBR2032 lithium non-rechargeable 4 year(s)
Protection typeShort-circuit protection transistor output Short-circuit and overload protection with automatic reset transistor output Reverse polarity protection transistor output Without protection relay output
Range of productModicon M241
Control signal typeA/B 100 kHz fast input (HSC mode) Pulse/direction 200 kHz fast input (HSC mode) Single phase 200 kHz fast input (HSC mode)
Discrete output typeTransistor Relay
Product or component typeLogic controller
Integrated connection typeNon isolated serial link serial 1 RJ45 RS232/RS485 Non isolated serial link serial 2 removable screw terminal block RS485 USB port mini B USB 2.0
Discrete input voltage typeDC
Surge withstand2 kV power lines (AC) common mode IEC 61000-4-5 2 kV relay output common mode IEC 61000-4-5 1 kV shielded cable common mode IEC 61000-4-5 1 kV power lines (AC) differential mode IEC 61000-4-5 1 kV relay output differential mode IEC 61000-4-5 1 kV input common mode IEC 61000-4-5 1 kV transistor output common mode IEC 61000-4-5
Output voltage limits125 V DC relay output 30 V DC transistor output 277 V AC relay output
Supply voltage limits85...264 V
Discrete input voltage24 V

All specifications

TM241C24R additional specifications
ParameterValue
Discrete output voltage5...125 V DC relay output 5...250 V AC relay output 24 V DC transistor output
Supply voltage100...240 V AC
Voltage state 0 guaranteed<= 5 V input
Voltage state 1 guaranteed>= 15 V input
Discrete input current5 mA input
Discrete output current2 A relay output Q4...Q9) 0.1 A fast output (PTO mode) TR0...TR3) 0.5 A transistor output TR0...TR3)
Sensor power supply24 V DC 400 mA supplied by the controller
Network frequency50/60 Hz
Maximum output frequency1 kHz transistor output 20 kHz fast output (PWM mode) 100 kHz fast output (PLS mode)
IP degree of protectionIP20 with protective cover in place
Communication port protocolNon isolated serial link Modbus master/slave
Mounting supportTop hat type TH35-15 rail IEC 60715 Top hat type TH35-7.5 rail IEC 60715 plate or panel with fixing kit
Electrical connectionremovable screw terminal block for inputs and outputs pitch 5.08 mm) removable screw terminal block for connecting the 24 V DC power supply pitch 5.08 mm)
Maximum cable distance between devicesUnshielded cable Shielded cable Unshielded cable Shielded cable <9.8 ft (3 m) fast output
Response time50 µs turn-on, I0...I13 input
Pollution degree2
Shock resistance15 gn 11 ms
Storage altitude0...9842.5 ft (0...3000 m)
Relative humidity10...95 %, without condensation in operation) 10...95 %, without condensation in storage)
Operating altitude0...6561.68 ft (0...2000 m)
Vibration resistance3.5 mm 5...8.4 Hz symmetrical rail 3 gn 8.4...150 Hz symmetrical rail 3.5 mm 5...8.4 Hz panel mounting 3 gn 8.4...150 Hz panel mounting
Depth3.7 in (95 mm)
Width5.9 in (150 mm)
Height3.5 in (90 mm)
StandardsANSI/ISA 12-12-01 CSA C22.2 No 142 CSA C22.2 No 213 IEC 61131-2:2007 Marine specification (LR, ABS, DNV, GL) UL 508
SupplySerial 1)serial link supply 5 V, <200 mA
MarkingCE
Accuracy+/- 0.1 % 0.02...0.1 kHz fast output +/- 1 % 0.1...1 kHz fast output
CategoryUS10MSX22533
InsulationBetween supply and internal logic 500 V AC Non-insulated between supply and ground
Reset time10 ms automatic reset output 12 s automatic reset fast output
Backup time2 years 77 °F (25 °C)
Clock drift<= 60 s/month 77 °F (25 °C)
Data backed up128 MB built-in flash memory backup of user programs
Realtime clockWith
Input impedance4.7 kOhm input
Memory capacity64 MB system memory RAM
Local signalling1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (red) for I/O error (I/O) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED (green) for SL2 1 LED (red) for bus fault on TM4 (TM4) 1 LED per channel (green) for I/O state
Transmission rate1.2...115.2 kbit/s (115.2 kbit/s by default) 49.2 ft (15 m) RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) 9.8 ft (3 m) RS232 480 Mbit/s 9.8 ft (3 m) USB
Discrete i (O number)24
Discrete input logicSink or source
Application structure4 cyclic master tasks 3 cyclic master tasks + 1 freewheeling task 8 external event tasks 8 event tasks
Counting input number4 fast input (HSC mode) 200 kHz 14 standard input 1 kHz
Discrete input number14, discrete input 8 fast input IEC 61131-2 Type 1
Discrete output logicPositive logic (source)
Positioning functionsPTO 4 100 kHz)
Data storage equipment<= 16 GB SD card optional)
Discrete output number6 relay 4 transistor 4 fast output
Immunity to microbreaks10 ms
Electromagnetic emissionConducted emissions 120...69 dBµV/m QP power lines)10...150 kHz IEC 55011 Conducted emissions 63 dBμV/m QP power lines)1.5...30 MHz IEC 55011 Conducted emissions 79 dBμV/m QP/66 dBμV/m AV power lines)0.15...0.5 MHz IEC 55011 Conducted emissions 73 dBμV/m QP/60 dBμV/m AV power lines)0.5...300 MHz IEC 55011 Radiated emissions 40 dBμV/m QP class A 10 m)30...230 MHz IEC 55011 Conducted emissions 79...63 dBμV/m QP power lines)150...1500 kHz IEC 55011 Radiated emissions 47 dBμV/m QP class A 10 m)230...1000 MHz IEC 55011
Configurable filtering time1 s fast input
Resistance to fast transients2 kV IEC 61000-4-4 power lines) 2 kV IEC 61000-4-4 relay output) 1 kV IEC 61000-4-4 serial link) 1 kV IEC 61000-4-4 input) 1 kV IEC 61000-4-4 transistor output)
Execution time for 1 KInstruction0.3 ms event and periodic task 0.7 ms other instruction
Ambient air temperature for storage-13...158 °F (-25...70 °C)
Resistance to conducted disturbances10 V 0.15...80 MHz IEC 61000-4-6 3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Resistance to electromagnetic fields9.1 V/m (10 V/m) 80 MHz...1 GHz IEC 61000-4-3 2.7 V/m (3 V/m) 1.4 GHz...2 GHz IEC 61000-4-3 0.9 V/m (1 V/m) 2 GHz...3 GHz IEC 61000-4-3
Ambient air temperature for operation14...122 °F (-10...50 °C) vertical installation) 14...131 °F (-10...55 °C) horizontal installation)
Resistance to electrostatic discharge8 kV in air IEC 61000-4-2 4 kV on contact IEC 61000-4-2

Product details

Compliance pack — what you get on paper

The TM241C24R: Marked CE, listed under UL 508, CSA C22.2 No 142 & 213, IEC 61131-2:2007, and carries marine approvals (LR, ABS, DNV, GL). Also meets ANSI/ISA 12-12-01 for Class I Division 2 hazardous locations. Pollution degree 2. The lifecycle field reads current — this isn’t a phase-out orphan; you can spec it into a BOM freeze without looking over your shoulder for an LTB window.

Panel fit — rail, plate, and the gap it needs

Width 150 mm, depth 95 mm, height 90 mm. Fastens onto a TH35-15 or TH35-7.5 DIN rail (IEC 60715) or plate-mounted with the fixing kit. Leaves 5.9 inches of rail space eaten up — plan neighboring terminals and a 24 V sensor supply draw of 400 mA. The backplane doesn’t supply the sensor loop; you pull that 24 V from the controller’s built-in sensor supply. Vibration tolerance: 3 gn at 8.4–150 Hz on the rail, half that if you panel-mount. Keep the cable glands tidy.

Frequently asked questions

What are the TM241C24R dimensions?

Width 150 mm (5.9 in), depth 95 mm (3.7 in), height 90 mm (3.5 in).

What compliance documentation does TM241C24R carry?

CE, UL 508, CSA C22.2 No 142/213, IEC 61131-2:2007, marine (LR, ABS, DNV, GL), and ANSI/ISA 12-12-01 for Class I Div 2.

MPN