Schneider Electric TM200C Series

11 variants · Schneider Electric

About the Schneider Electric TM200C Series

AO Ctrl is an independent industrial automation distributor and independent stocking center for Schneider Electric TM200C Series components — the parts engineering, repair and maintenance teams source here when lines face allocation constraints or urgent machine-down emergencies — with the physical condition of every unit verified up front. The Schneider Electric TM200C Series series groups 11 related part numbers, each listed with full specifications, a datasheet where available, and an RFQ option. Every variant in the range shares a common backup time of 3 years at 25 °C (by interruption of power supply), depth of 70 mm and height of 90 mm. Variants differ by width and response time, so you can match the exact width your application requires using the selection guide below. All listed Schneider Electric TM200C Series part numbers are active and orderable.

Select a variant by

Width
110 mm · 130 mm · 175 mm · 225 mm
Response time
1 ms turn-on, Q0...Q9 terminal(s) for output 1 ms turn-off, Q0...Q9 terminal(s) for output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input · 1 ms turn-on, Q0...Q15 terminal(s) for output 1 ms turn-off, Q0...Q15 terminal(s) for output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 125 µs turn-off, I14...I23 terminal(s) for regular input 55 µs turn-on, I14...I23 terminal(s) for regular input · 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 10 ms turn-off, Q0...Q9 terminal(s) for relay output 10 ms turn-on, Q0...Q9 terminal(s) for relay output 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input · 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 10 ms turn-off, Q0...Q15 terminal(s) for relay output 10 ms turn-on, Q0...Q15 terminal(s) for relay output 125 µs turn-off, I14...I23 terminal(s) for regular input 55 µs turn-on, I14...I23 terminal(s) for regular input · 10 ms turn-on, Q0...Q11 terminal(s) for output 10 ms turn-off, Q0...Q11 terminal(s) for output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 125 µs turn-off, I14...I19 terminal(s) for regular input 55 µs turn-on, I14...I19 terminal(s) for regular input · 10 ms turn-on, Q0...Q23 terminal(s) for output 10 ms turn-off, Q0...Q23 terminal(s) for output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 125 µs turn-off, I14...I35 terminal(s) for regular input 55 µs turn-on, I14...I35 terminal(s) for regular input

Shared specifications

Backup time
3 years at 25 °C (by interruption of power supply)
Depth
70 mm
Height
90 mm
Input impedance
3.3 kOhm for discrete input
IP rating
IP20
Main product or component type
Logic controller
Operating temperature
0...55 °C (horizontal installation)
Pollution degree
<= 2
Storage temperature
-25...70 °C
Temp operating max
55 °C
Temp operating min
0 °C
Temp storage max
70 °C

Variant comparison

ParameterTM200CE40RTM200CE40TTM200C60RTM200C40TTM200C40RTM200CE32R
Width175 mm175 mm225 mm175 mm175 mm175 mm
Response time5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 10 ms turn-off, Q0...Q15 terminal(s) for relay output 10 ms turn-on, Q0...Q15 terminal(s) for relay output 125 µs turn-off, I14...I23 terminal(s) for regular input 55 µs turn-on, I14...I23 terminal(s) for regular input1 ms turn-on, Q0...Q15 terminal(s) for output 1 ms turn-off, Q0...Q15 terminal(s) for output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 125 µs turn-off, I14...I23 terminal(s) for regular input 55 µs turn-on, I14...I23 terminal(s) for regular input10 ms turn-on, Q0...Q23 terminal(s) for output 10 ms turn-off, Q0...Q23 terminal(s) for output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 125 µs turn-off, I14...I35 terminal(s) for regular input 55 µs turn-on, I14...I35 terminal(s) for regular input——10 ms turn-on, Q0...Q11 terminal(s) for output 10 ms turn-off, Q0...Q11 terminal(s) for output 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input 125 µs turn-off, I14...I19 terminal(s) for regular input 55 µs turn-on, I14...I19 terminal(s) for regular input

Request a quote on any Schneider Electric TM200C Series part number and we confirm price, availability and lead time per line — including end-of-life, allocation-constrained, and machine-down urgent requirements.

About Schneider Electric Schneider Electric TM200C Series Sourcing

What buyers ask when they search Schneider Electric TM200C Series Industrial Component Specifications Datasheet.

Frequently Asked Sourcing & Technical Questions

Q:What is the Schneider Electric TM200C Series used for?

Engineers searching for this product series need to understand the application scope before comparing specific part numbers.

Q:How do I select the correct part number within the Schneider Electric TM200C Series series?

The series includes 11 variants — understanding the key selection parameters avoids ordering incorrect configurations.

Q:What are the key technical specifications for the Schneider Electric TM200C Series?

Buyers comparing alternatives need to verify rated values match their application requirements before requesting a quote.

Q:Where can I find the Schneider Electric TM200C Series datasheet and order from authorized distributors?

Procurement professionals need verified distributor sources for authentic parts with traceable supply chains.

All variants

3 products