Siemens 3RT1055-6NP36-3PA0 SIRIUS Power Contactor, Size S6,

MPN3RT1055-6NP36-3PA0
Active

Siemens SIRIUS, power contactor, Size S6, 3RT1055-6NP36-3PA0, 200-277 V AC coil, screw-type terminals, screw fixing, 25-120 mm² main conductor cross-section.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1055-6NP36-3PA0 — Identification
ParameterValue
Contactor frame sizeS6
3RT1055-6NP36-3PA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V132 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V30 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1055-6NP36-3PA0 — Control & Coil
ParameterValue
Control supply voltage typeAC/DC
Rated value @ 50 Hz0.6
Rated value @ 50 Hz200 ... 277 V
3RT1055-6NP36-3PA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1055-6NP36-3PA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 355 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegG: 315 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 315 A (415 V, 50 kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT1055-6NP36-3PA0 — Connection & Mounting
ParameterValue
Main circuit connectionConnection bar
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), max. 2x (0,75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew fixing
Side-by-side mountingYes
3RT1055-6NP36-3PA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1055-6NP36-3PA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1055-6NP36-3PA0 — Mechanical
ParameterValue
Width120 mm
Height172 mm
Depth170 mm
3RT1055-6NP36-3PA0 — Specifications
ParameterValue
At AC80 ... 90 ms

Product details

SIRIUS Size S6 Power Contactor — 200-277 V Coil, Screw Fixing

The coil is rated 200-277 V AC, so it lands squarely on standard three-phase control transformers without needing an intermediate relay. Screw fixing to the mounting plate and screw-type coil terminals keep wiring straightforward for panel builders. Main power circuit accepts stranded conductors from 25 to 120 mm², sized for the S6 frame's typical motor currents. Auxiliary switch is included on the unit, with its own screw terminals accepting 2x (0.5-1.5 mm²) solid, 2x (0.75-2.5 mm²) solid, or up to 2x (0.75-4 mm²) stranded — enough for control-wire terminations without a separate terminal block.

Duty Ratings and Switching Frequency

The contactor's operating life and thermal limits depend on the duty class. At AC-3 (squirrel-cage motor starting) it manages up to 750 switching cycles per hour; at AC-4 (plugging/reversing/inching) that drops to 130 cycles per hour. AC-1 resistive loads allow 800 cycles per hour. Operate time is 80-90 ms on both AC and DC coil supplies, and arcing time runs 10-15 ms. The power factor at 50 Hz and 60 Hz is 0.6, which matters when sizing control transformers for a bank of contactors.

Dimensions are 172 mm height, 120 mm width, 170 mm depth. Four mounting holes at 9 mm diameter on a single-hole pattern per pole.

The built-in auxiliary switch is rated 10 A at 24 V, 2 A at 48 V, 2 A at 60 V, and 1 A at 110 V. These are the figures to check when the auxiliary feeds a PLC input or a pilot light — the 24 V rating is generous, but the 110 V rating drops to 1 A, so a multi-lamp indication circuit could exceed it.

Frequently asked questions

How do I get current pricing and availability for 3RT1055-6NP36-3PA0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is 3RT1055-6NP36-3PA0's listed depth?

The depth is 170 mm.

What wire sizes does the auxiliary terminal accept?

The auxiliary switch terminals accept 2x (0.5-1.5 mm²) solid, 2x (0.75-2.5 mm²) solid, or up to 2x (0.75-4 mm²) stranded.

Will 3RT1055-6NP36-3PA0 drop into a panel specified around 3RT1055-6QF35 without rewiring?

Both are Size S6 SIRIUS contactors with screw fixing and the same 172 x 120 x 170 mm footprint, so the mechanical swap is direct. The coil voltage differs — this unit is 200-277 V AC versus the 6QF35's coil — so verify the control transformer matches before installing.

MPN
3RT1055-6NP36-3PA0