Skip to main content
Siemens 3VA1010-2ED32-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1010-2ED32-0BH0 MCCB, 100 A, 3-Pole, Line

MPN3VA1010-2ED32-0BH0

Siemens SENTRON molded case circuit breaker, 3VA1010-2ED32-0BH0, 3-pole, 100 A, line protection, with undervoltage release and auxiliary switches.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1010-2ED32-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10102ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1010-2ED32-0BH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.27.5 W
3VA1010-2ED32-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1010-2ED32-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1010-2ED32-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1010-2ED32-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1010-2ED32-0BH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

It carries a 52.5 kA interrupting capacity at 240 V, derating to 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V — so the available fault current at the installation point determines which voltage column governs the selection.

Above that, it derates: 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard SENTRON 3VA footprint that fits the DIN-rail mounting grid. That heat must be dissipated within the enclosure; for a multi-breaker panel, sum the losses and check the cabinet's thermal budget.

Operating environment and lifecycle

This is a line-protection device (not motor-protection or ground-fault), so it is sized for feeder or main breaker duty where overcurrent and short-circuit protection of cable and bus is the primary function.

Frequently asked questions

Where can I buy 3VA1010-2ED32-0BH0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 3VA1010-2ED32-0BH0 at different voltages?

The interrupting capacity is 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V. Select the voltage column that matches your system's available fault current.

What does the undervoltage release on this MCCB do?

The undervoltage release (UVR) trips the breaker when the control voltage falls below its dropout threshold. It is used in safety circuits where loss of control power must open the main contacts — for example, in emergency-stop chains or mains-monitoring applications.

MPN
3VA1010-2ED32-0BH0