Skip to main content
Siemens 3VA1063-2ED36-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED36-0AC0 SENTRON MCCB, 63 A, 52.5 kA at 24

MPN3VA1063-2ED36-0AC0

Siemens SENTRON 3VA1063-2ED36-0AC0, molded case circuit breaker, 3-pole, 63 A, TM210 overcurrent release, 52.5 kA at 240 V, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1063-2ED36-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10632ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1063-2ED36-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.17.3 W
3VA1063-2ED36-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1063-2ED36-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED36-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1063-2ED36-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED36-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1063-2ED36-0AC0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying 63 A continuously at 40 °C with no derating needed up to 50 °C — it holds 63 A flat through that range, then tapers to 58 A at 70 °C. The TM210 thermal-magnetic release handles overload and short-circuit trip curves, and the interrupting capacity hits 52.5 kA at 240 V AC, 32 kA at 415 V, and 7.5 kA at 690 V. That means it can clear high-fault currents on a 240 V distribution bus without upstream fuses needing to open first.

At 76.2 mm wide, 130 mm tall, and 70 mm deep, this MCCB fits standard SENTRON 3VA panel cutouts and busbar systems.

Frequently asked questions

What is the breaking capacity of this MCCB at 240 V?

52.5 kA at 240 V AC, with 32 kA at 415 V and 7.5 kA at 690 V.

Where can I buy 3VA1063-2ED36-0AC0 and how is it quoted?

This part is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — stock and lead time are confirmed at quote time.

What does the TM210 release designation mean?

TM210 is a thermal-magnetic release with a fixed thermal rating of 63 A and a magnetic trip threshold set at 10x In (630 A) for short-circuit protection.

MPN
3VA1063-2ED36-0AC0