Siemens 3VA1063-2ED36-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1063-2ED36-0AD0 SENTRON MCCB, 63 A, 3-Pole, TM210

MPN3VA1063-2ED36-0AD0

Siemens SENTRON 3VA series, molded case circuit breaker, 3VA1063-2ED36-0AD0, 3-pole, 63 A, TM210 thermal-magnetic release, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1063-2ED36-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10632ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1063-2ED36-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C62 A
Current at 60 °C61 A
Current at 65 °C60 A
Current at 70 °C58 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.17.3 W
3VA1063-2ED36-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1063-2ED36-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1063-2ED36-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3
3VA1063-2ED36-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1063-2ED36-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens 3VA1063-2ED36-0AD0 is a SENTRON 3VA molded case circuit breaker rated for line protection, carrying a 63 A continuous current at 40 °C ambient with no derating needed up to 50 °C — it holds 63 A flat through 50 °C, then drops to 62 A at 55 °C, 61 A at 60 °C, 60 A at 65 °C, and 58 A at 70 °C, so in a warm enclosure you still have headroom before the thermal element nudges the trip curve. The TM210 overcurrent release is a thermal-magnetic design — the thermal bimetal handles overload protection (inverse-time), the magnetic coil handles short-circuit instantaneous trip. Breaking capacity climbs with available fault current: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V. Three-pole, 70 mm deep, 76.2 mm wide, 130 mm tall — standard 3VA frame footprint. The 17.3 W maximum power loss at rated current is the heat you need to vent in a sealed enclosure; at 63 A that is about 0.27 W per amp, which is typical for a thermal-magnetic MCCB of this frame size.

Spring-cage or screw terminals on the load side — the order code variant determines termination; this code ships with the standard screw terminals for the 3VA frame. The auxiliary switch block (3 auxiliary switches HQ) is a separate orderable accessory that clips onto the left side of the breaker — it is not integrated into this base unit. If you need a trip-indicated auxiliary contact, order the switch block separately and snap it on before panel wiring.

Frequently asked questions

How do I get current pricing and availability for 3VA1063-2ED36-0AD0?

Submit an RFQ against this order code. Availability and current pricing are confirmed at quote time through independent distribution; no stock or price figures are published here.

What is the breaking capacity of 3VA1063-2ED36-0AD0 at 415 V?

32 kA at 415 V, with higher values at lower voltages — 52.5 kA at 240 V — and 7.5 kA at both 500 V and 690 V.

Will 3VA1063-2ED36-0AD0 drop into a panel specified around 3VA1110-5ED36-0AC0?

No — the 3VA1110-5ED36-0AC0 is a 100 A frame (wider footprint and different mounting hole pattern) versus the 63 A frame of this unit. The physical dimensions differ: this breaker is 76.2 mm wide versus the 100 A frame's larger width, so it will not bolt into the same bus bars or DIN-rail position without re-spacing.

What compliance documentation does Siemens provide for this MCCB?

Siemens SENTRON 3VA breakers carry UL 489, CSA C22.2 No. 5, and IEC 60947-2 certifications. RoHS and REACH declarations are available through the Siemens Industry Online Support portal for this order code.

MPN
3VA1063-2ED36-0AD0