Skip to main content
Siemens 3VA2140-6HN46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-6HN46-0AA0 SENTRON MCCB, 40 A, 4-Pole, 242 k

MPN3VA2140-6HN46-0AA0
Active

Siemens SENTRON 3VA2140-6HN46-0AA0, molded case circuit breaker, 4-pole, 40 A (Iu), 242 kA at 240 V, ETU350 electronic trip unit, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-6HN46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2140-6HN46-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W
3VA2140-6HN46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2140-6HN46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-6HN46-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-6HN46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-6HN46-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

It's built for line protection in distribution panels where you need high interrupting capacity — 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V, and still 3.7 kA at 690 V. That kind of SCCR headroom means it can sit upstream of a fault without cascading, which is what you want when you're coordinating a main or a large feeder in an industrial switchboard.

Ratings that matter for the panel

That's unusual for an MCCB and simplifies panel thermal calculations. The ETU350 electronic trip gives you adjustable overload and short-time protection curves, plus the N-conductor protection can be set OFF or 100% — handy for 4-wire systems where you want to detect a lost neutral without nuisance tripping.

Power loss is only 1.6 W max, so heat buildup in a dense enclosure is negligible.

Frequently asked questions

How do I get current pricing and availability for 3VA2140-6HN46-0AA0?

Submit an RFQ through this listing. We source through independent distribution and confirm price and availability at quote time — no automated stock figures here.

What is the interrupting capacity of 3VA2140-6HN46-0AA0?

242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V.

Does 3VA2140-6HN46-0AA0 drop into a panel wired for 3VA2116-5JP32-0AE0?

Both are 4-pole SENTRON MCCBs with similar frame sizes, but verify the mounting footprint and terminal spacing against your panel layout — the 140 mm width and 86 mm depth are the same class, but always check the drilling plan before committing the BOM.

MPN