Specifications

A9F04413 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04413 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04413 is an Acti9 iC60N miniature circuit breaker rated at 13 A with 4 protected poles and a C-curve trip characteristic. It carries a 36 kA Icu breaking capacity at 12–133 V AC and 10 kA Icu at 380–415 V AC per EN/IEC 60947-2, plus a 6 kA Icn at 400 V AC per EN/IEC 60898-1. That dual-standard rating means it can serve both industrial panel distribution (60947-2) and final-circuit protection (60898-1) in the same enclosure — useful when a single breaker must satisfy both a machine builder's SCCR requirement and the local wiring code.

The 36 kA Icu at low voltage (12–133 V AC) is the headline number, but the figure that governs most 400 V panel designs is the 10 kA Icu at 380–415 V AC. That is the rating the upstream transformer and bus bracing must coordinate with. The C-curve magnetic trip is set at 8 x In ±20 %, so on a 13 A breaker the instantaneous trip starts around 83 A and is guaranteed by 125 A — fast enough to clear a bolted fault before the upstream device sees it, provided the let-through energy (limitation class 3 per EN/IEC 60898-1) stays within the downstream cable's withstand.