A9F77325 Acti9 iC60N MCB, 25 A, 3P, C-Curve, 36 kA

MPN A9F77325
Active

Schneider Electric Acti9 iC60N, A9F77325, miniature circuit breaker, 25 A, 3P, C-curve, 36 kA Icu at 12-133 V AC, DIN rail mount.

$74.01 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F77325 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F77325 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

What the ratings mean for fit

The A9F77325 is a 25 A rated, 3-pole miniature circuit breaker from the Acti9 iC60N range. The C-curve (magnetic trip at 8 x In ±20%) means it handles moderate inrush from motor starters, small transformers, and lighting banks without nuisance tripping — a typical choice for general distribution circuits in commercial and light industrial panels. Breaking capacity is the headline number that decides whether this breaker holds in a high-fault location. At 36 kA Icu (12–133 V AC) it clears severe faults near the service entrance; at 20 kA (220–240 V) it covers most panelboard mains; at 10 kA (380–415 V) it suits sub-distribution boards. The 6 kA rating at 440 V AC is the tail-end — verify the available fault current at the installation point before committing the BOM line. Dual-rated to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / commercial), so it qualifies for either duty class. Pollution degree 3 and overvoltage category IV mean it's rated for the harsh electrical environment of a main distribution board — not just a clean sub-panel.

Panel integration and mounting

Snaps onto a standard DIN rail (mounting support per). The 54 mm width × 85 mm height × 78.5 mm depth footprint occupies 6 x 9 mm pitches — count the rail space before laying out a multi-pole group. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible; strip length 14 mm, torque to 2 N·m. IP20 finger-safe terminals suit enclosed panels; no washdown rating here.