Skip to main content
Schneider Electric A9L40100

Schneider Electric A9L40100 Acti9 iPRD40 Type 2 Surge Arrest

MPN A9L40100
Active

Schneider Electric Acti9 iPRD40, Type 2 surge arrester, 1P, 350 V, 40 kA max discharge, pluggable cartridge, clip-on DIN rail.

$57.20 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9L40100 specifications
ParameterValue
Voltage230 V AC (+/- 10 %) at 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Storage temperature-40...85 °C
ColorWhite (RAL 9003)
Depth69 mm
Width18 mm
Height85 mm
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9L40100 is an Acti9 iPRD40 Type 2 surge arrester with a pluggable MOV cartridge, rated for 230 V AC (+/- 10 %) at 50/60 Hz on TN-C and IT 230 V earthing systems. The 40 kA common-mode maximum discharge current (L/PE) and 15 kA nominal discharge current cover most service-entrance and sub-distribution panel surge requirements.

Type 2 per EN 61643-11:2012 and IEC 61643-11:2011 means this arrester is designed for the main or sub-distribution board, clamping switching transients and indirect lightning surges before they reach downstream equipment. The 350 V maximum continuous operating voltage (Uc) matches 230/400 V TN systems with up to +10 % steady-state tolerance. The temporary overvoltage withstand of 337 V for 5 seconds (L/N) and 1200 V for 200 ms (N/PE) in safe failure mode means the MOV can ride through a brief overvoltage without catastrophic failure — important for utility-switching events. The voltage protection level (Up) is under 1.4 kV, which keeps let-through voltage low enough to protect most IEC 60947-2-listed circuit breakers and contactors in the same panel.

Clip-on DIN rail mount (EN 60715). Tunnel terminals on both top and bottom accept 2.5 to 35 mm² conductors; tighten to 2.5 N·m. The 85 mm height and 69 mm depth are standard for Acti9 modular devices, so it aligns with adjacent MCBs and RCDs on the same rail. The white housing (RAL 9003) matches the rest of the Acti9 range.

Associated overcurrent protection

The manufacturer specifies several associated circuit breakers or fuses to back up the arrester: iC60H 40 A curve C (Icu 15 kA), iC60N 40 A curve C (Icu 10 kA), NG125H/N/L 40 A curve C (Icu 25–50 kA), or gG fuses up to 80 A. This lets the panel builder match the SCCR of the distribution board without oversizing the arrester branch. The iPRD40 itself does not include a disconnector — it relies on the upstream device for fault current interruption.

MPN
A9L40100