Skip to main content
Schneider Electric A9L65301

A9L65301 Acti9 iPRD65r Type 2 Surge Arrester, 3P, 65 kA

MPN A9L65301
Active

Schneider Electric Acti9 iPRD65r, Type 2 surge arrester, 3P, 400 V AC, 65 kA max discharge, pluggable cartridge, DIN rail mount.

$154.82 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9L65301 specifications
ParameterValue
Voltage400 V AC (+/- 10 %) at 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Storage temperature-40...85 °C
ColorWhite (RAL 9003)
Depth69 mm
Width54 mm
Height85 mm
ApplicationDistribution
Operating temperature-25...60 °C

Product details

Type 2 surge arrester for 400 V distribution boards

The Schneider Electric A9L65301 is an Acti9 iPRD65r Type 2 surge arrester in a 3-pole (3P) configuration, rated for 400 V AC (+/- 10 %) at 50/60 Hz distribution networks. This is a current-production part (lifecycle stage: current). The unit uses a hybrid MOV + GDT (Metal Oxide Varistor plus Gas Discharge Tube) technology, which reduces leakage current and extends service life compared to MOV-only designs. The pluggable cartridge means the active protection element can be replaced without rewiring the base — a practical advantage during commissioning or after a severe surge event.

Discharge ratings and protection levels

Nominal discharge current (In) is 20 kA per mode (L/PE, N/PE, L/N), and maximum discharge current (Imax) is 65 kA per mode. The voltage protection level (Up) is <1.5 kV for both common and differential modes — this is the let-through voltage the protected equipment sees. For a Type 2 device installed at the sub-distribution board, that keeps downstream equipment within typical impulse withstand ratings. Maximum continuous operating voltage (Uc) is 350 V L/PE and L/N, and 260 V N/PE. Temporary overvoltage (Ut) withstand is 337 V L/N for 5 seconds; the N/PE path is rated for 1200 V for 200 ms in safe failure mode — relevant for TN-C and IT earthing systems (the arrester is explicitly listed for TN-C IT 230 V systems).

Integration and disconnector coordination

The iPRD65r requires an upstream overcurrent protective device. The manufacturer specifies associated circuit breakers: IC60N, iC60H, NG125N, NG125H, or NG125L, all 50 A curve C, or a gG 80 A fuse. The disconnector type is listed as 'associated circuit breaker' or 'associated fuse' — the installer must select one from the table to ensure coordination and to avoid the arrester becoming a fault path. Tunnel-type terminals accept 2.5 to 35 mm² conductors on both the line and load sides; tightening torque is 2.5 N·m. Remote signalling is provided via a changeover contact (1 SD, 1 C/O) rated at 0.25 A / 250 V AC. This allows the arrester's end-of-life or disconnected state to be monitored by a PLC or building management system — useful for panels where visual inspection is impractical.

Relative humidity tolerance is 5 to 95 %. Maximum operating altitude is 2000 m. The enclosure carries an IK03 impact rating per IEC 62262. Certified to EN 61643-11:2012 and IEC 61643-11:2011, with KEMA-KEUR and NF marks. Ground residual current is 0.6 mA and 0.003 mA.

MPN