Skip to main content
Schneider Electric A9N19641

Schneider Electric A9N19641 Acti9 DPN Vigi RCBO, 6 A Type C,

MPN A9N19641
Obsolete

Schneider Electric Acti9 DPN Vigi earth leakage circuit breaker, A9N19641, Type A-SI (Super Immunised), 6 A rated, C-curve, 30 mA sensitivity, 6 kA breaking capacity.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19641 specifications
ParameterValue
Control typeToggle
Product typeType A-SI (Super Immunised)
Trip unit typeThermal-magnetic
Main product or component typeEarth leakage circuit breaker
Voltage230 V AC
Insulation voltage ui400 V AC conforming to EN 61009
Breaking capacity6000 A Icn at 230 V AC conforming to EN 61009
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to EN 61009
ColorWhite
Electrical life cycles20000 cycles conforming to IEC 61009
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9N19641 is an Acti9 DPN Vigi earth leakage circuit breaker — an RCBO that combines overcurrent protection (6 A, C curve) and residual current protection (30 mA) in a single 1P+N module. That makes it suitable for circuits feeding IT equipment, LED lighting, or small drives where a standard Type A would false-trip.

Rated Icn of 6000 A at 230 V AC per EN 61009. That is the standard domestic and light commercial interrupting rating in most European installations. The 6 A C-curve thermal-magnetic trip unit provides magnetic tripping between 5 and 10 x In, so it clears moderate inrush from small motor loads or capacitive supplies without delay. For selectivity with an upstream 63 A gG fuse or a 16 A MCB, the 6 kA rating is adequate for typical fault levels in final sub-circuits; coordination tables should be verified at the design stage.

Snaps onto standard DIN rail. Neutral is on the left, phase on the right; the outgoing terminals accept up to 10 mm² flexible or 16 mm² rigid cable via tunnel-type terminals. The toggle provides local ON/OFF indication, and the contact position indicator confirms the main contacts are open.

MPN
A9N19641