A9N19754 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz
Breaking capacity6000 A Icn at 220...240 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Terminal pitch9 mm between phase and neutral
Temp storage max70 °C
Temp storage min-30 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-30...70 °C
Pollution degree3

All specifications

A9N19754 additional specifications
ParameterValue
ColorWhite
Depth77.5 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The B curve means magnetic tripping occurs between 3 and 5 times the rated current (30–50 A).

Breaking capacity is 6 kA Icn at 230 V AC, 50/60 Hz, certified to EN/IEC 61009-2-1. That's the standard domestic and light-commercial fault level; if your point-of-supply prospective short-circuit current exceeds 6 kA, you'll need to coordinate upstream or step to a higher-rated device. The thermal-magnetic trip unit handles overloads (thermal) and short-circuits (magnetic). Limitation class 3 means it restricts let-through energy enough to protect downstream cables and equipment in most installations. Integrated earth-leakage protection saves a module of DIN rail space compared to a separate MCB + RCCB pair. The neutral is on the left (fixed position), and the device switches both phase and neutral — the neutral pole is not just a solid link but a switched pole, which is required in some national wiring rules.

Installation and environment

Strip length 15 mm. The device occupies 4 module pitches (36 mm wide, 81 mm tall, 77.5 mm deep). IP20 on the body, IP40 inside the modular enclosure. Pollution degree 3, overvoltage category III.

MPN
A9N19754