Skip to main content
Schneider Electric A9N1P03CIN

Schneider Electric A9N1P03CIN Acti9 xC60 MCB, 3 A, 1P, C-Cur

MPN A9N1P03CIN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P03CIN, 1-pole, 3 A, C-curve, 10 kA breaking capacity at 240 V AC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P03CIN key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 12...48 V DC 60 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Breaking capacity10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

A9N1P03CIN additional specifications
ParameterValue
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N1P03CIN is a 1-pole miniature circuit breaker from the Acti9 xC60 series, rated 3 A with a C-curve trip characteristic. Breaking capacity is 10 kA Icu at 240 V AC, 15 kA at 12–48 V DC, and 6 kA at 60 V DC, all per IS/IEC 60947-2.

The 3 A C-curve is the key selection gate: C-curve trips magnetically at 5–10 x In (here 15–30 A), so it handles moderate inrush from small transformers, lighting ballasts, or control circuits without nuisance trips. The thermal-magnetic trip unit means bimetal for overload, solenoid for short — no electronics to drift. Overvoltage category IV means this breaker is rated for the mains supply entry point — it can handle the transient energy at the service entrance, not just downstream sub-panels. Suitability for isolation per IS/IEC 60947-2 means you can safely use it as a disconnecting means for the downstream circuit during maintenance, provided it's locked off.

Wire strip length is 13 mm for top or bottom connection. IP20 finger-safe terminals — fine inside a locked panel, not for wet locations.