Skip to main content
Schneider Electric A9N2P25CIN

Schneider Electric A9N2P25CIN Acti9 xC60 MCB, 25 A, C-Curve,

MPN A9N2P25CIN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N2P25CIN, 2-pole, 25 A, C-curve, 10 kA breaking capacity at 415 V AC, 35 mm DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N2P25CIN key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C

All specifications

A9N2P25CIN additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N2P25CIN is a 2-pole miniature circuit breaker from the Acti9 xC60 range, rated 25 A with a C-curve trip characteristic. The C-curve means magnetic tripping occurs at 8 x In (200 A) ±20% — designed for inductive loads like motor starters and small transformers where inrush current exceeds resistive load levels. The 10 kA breaking capacity at 380…415 V AC (IS/IEC 60947-2) tells you this MCB can safely interrupt a fault current up to 10,000 A without welding its contacts or cascading failure upstream. For DC circuits, the rated breaking capacity is 6 kA at 100…125 V DC, so it handles moderate DC faults but not high-voltage DC bus work.

Width is 36 mm — 4 x 9 mm pitches — so it occupies two standard modular positions on the rail. Depth of 77.5 mm and height of 85 mm mean it fits most distribution boards without crowding the gland plate. Wire stripping length is 13 mm for top or bottom connection. IP20 finger-safe protection is fine for enclosed panels; not rated for washdown environments.

Limitation class 3 per that standard means it limits let-through energy well — useful for downstream component protection.

MPN
A9N2P25CIN