Skip to main content
Schneider Electric A9N60708

Schneider Electric A9N60708 Acti9 C120 MCB, 80 A, 1P, C-Curv

MPN A9N60708
Active

Schneider Electric Acti9 C120, miniature circuit breaker, 1P, 80 A, C-curve, 5 kA Icu at 230...400 V AC, thermal-magnetic, clip-on DIN rail.

$23.09 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N60708 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity5 kA Icu at 230...400 V AC 50/60 Hz conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

A9N60708 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width27 mm
Height81 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N60708 is a 1-pole miniature circuit breaker from the Acti9 C120 range, rated 80 A at 40 °C with a C-curve trip characteristic. It clips onto a 35 mm symmetrical DIN rail — standard for panel and enclosure builds — and occupies 3 x 9 mm pitches (27 mm wide). The thermal-magnetic trip unit handles distribution-level overcurrent and short-circuit protection, with a magnetic tripping limit of 8 x In ±20 %.

Rated 5 kA Icu at 230...400 V AC 50/60 Hz per EN/IEC 60947-2. The limitation class is 3 per the same standard, meaning it lets through less energy during a fault, which helps with downstream coordination.

Installation and wiring constraints

Tunnel-type terminals accept 1...50 mm² rigid or 1.5...35 mm² flexible cable. Wire stripping length is 15 mm for both top and bottom connections. Tightening torque: 3.5 N·m. The toggle gives local ON/OFF indication, and the contact position indicator confirms the state visually. Padlock provision is included for lockout/tagout procedures.

MPN
A9N60708