Schneider Electric A9R11225

Schneider Electric A9R11225 Acti9 iID RCCB, 25A 30mA 2P Type

MPN A9R11225
Obsolete

Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), A9R11225, 25 A, 30 mA, 2P, Type AC, 220-240 V AC, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R11225 specifications
ParameterValue
Control typeToggle
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width36 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9R11225 is an Acti9 iID residual current circuit breaker (RCCB) — a 2-pole, Type AC device rated for 25 A continuous load with 30 mA earth-leakage sensitivity.

The 30 mA sensitivity is the standard threshold for personal protection against indirect contact in residential and commercial final circuits — it trips on leakage currents above that level, not on overload or short-circuit (that's the MCB's job upstream). The 25 A rated current (In) matches a 25 A MCB in the same distribution board for a coordinated outgoing circuit. For variable-speed drives, UPS outputs, or LED drivers with rectifier stages, a Type A or Type F RCCB would be required instead. In a domestic or light commercial panel with a typical prospective short-circuit current under 1500 A, it's adequate; for industrial boards with higher fault levels, verify the upstream protection limits the let-through. Voltage-independent tripping means the RCCB will still open on an earth fault even if the phase voltage collapses — the trip energy comes from the fault itself, not the supply. This is standard for electromechanical RCCBs and gives reliable protection regardless of supply conditions. The 8/20 µs impulse withstand of 250 A means it survives common lightning-induced surge currents without nuisance tripping — important for outdoor-fed circuits or areas with frequent storms.

This outgoer device sits downstream of the main switch or incoming MCB, protecting a final sub-circuit. The 2-pole (2P) configuration switches both phase and neutral. Clip-on mounting to a 36 mm wide DIN-rail footprint (4 x 9 mm pitches) means it snaps directly into a standard distribution board alongside Acti9 MCBs and other modular devices. The white housing matches the Acti9 family aesthetic for clean panel layouts. Terminals accept up to 35 mm² rigid or 25 mm² flexible cable — sufficient for a 25 A circuit with typical 4 mm² or 6 mm² final sub-main wiring. Torque to 3.5 N·m. Strip length is 14 mm.

It carries EN/IEC 61008-1 certification, which is the harmonized European standard for RCCBs. This is the compliance basis for CE marking and acceptance in most countries that follow IEC wiring rules. No UL listing — this is an IEC-market device, not intended for North American panels.