Skip to main content
Schneider Electric A9T27606

A9T27606 Acti9 iDPN H VigiArc RCBO, 6 A, C-curve, 10 kA

MPN A9T27606
Obsolete

Schneider Electric Acti9 iDPN H VigiArc RCBO, 1P+N, 6 A, C-curve, 10 kA breaking capacity, integrated earth-leakage protection, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9T27606 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeArc fault detection RCBO
Voltage230/240 V AC 50 Hz conforming to AS/NZS 61009.1 230/240 V AC 50 Hz conforming to IEC 62606
Insulation voltage ui250 V AC 50 Hz between phase and neutral 400 V AC 50 Hz between phases
Breaking capacity10000 A at 240 V AC 50 Hz conforming to AS/NZS 61009.1
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...80 °C

All specifications

A9T27606 additional specifications
ParameterValue
Pollution degree2 conforming to AS/NZS 61009.1 2 conforming to IEC 62606
ColorWhite
Depth75 mm
Width36 mm
Height91 mm
Electrical life cycles20000 cycles 240 V AC 50 Hz conforming to AS/NZS 61009.1
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

Acti9 iDPN H VigiArc — RCBO with integrated arc-fault and earth-leakage detection

It combines a 6 A thermal-magnetic MCB (C-curve, 5...10 x In magnetic trip) with integrated earth-leakage and arc-fault detection per EN/IEC 62606 and AS/NZS 61009.1.

The 6 A rated current (In) governs conductor sizing and load — this unit protects a final subcircuit, not a main feeder. The integrated earth-leakage detection (no external RCCB needed) and arc-fault sensing (VigiArc) reduce panel space and wiring complexity: one DIN-rail module handles overcurrent, residual current, and series/parallel arc faults. Limitation class 3 per AS/NZS 61009.1 limits let-through energy under fault, supporting downstream device coordination. Mechanical and electrical durability are both rated at 20,000 cycles — sufficient for normal switching duty in a panel, but not for frequent on/off load-break applications.

Deployment context

The device sits as an outgoer in the distribution board, with top and bottom cable entry. Tropicalisation severity B per IEC 60068-2-30 (28-day damp-heat cycle) confirms suitability for high-humidity environments up to 95% RH at 55 °C, which matters for coastal or unconditioned plant rooms.

MPN
A9T27606