Skip to main content
Schneider Electric ATV1200A14305555

Schneider Electric ATV1200A14305555 AC Drive, 1195 kW

MPN ATV1200A14305555
Active

Schneider Electric Altivar 1200 series, ATV1200A14305555 AC drive, 1195 kW motor power, 1430 kVA apparent power, 2970-3630 V supply, 30-pulse rectifier, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A14305555 specifications
ParameterValue
Input type30 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current150 A
IP ratingIP41 / IP42 / IP31
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1600 mm (high efficiency) 1500 mm (standard efficiency)
Width3960 mm (high efficiency) 3660 mm (standard efficiency)
Height2820 mm standard efficiency 2820 mm high efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

Active production — what that means for procurement

The ATV1200A14305555: Sourced through authorized distribution channels against your BOM quantity.

Power rating and overload — sizing the drive to the load

Rated for 1195 kW motor power with 1430 kVA apparent power. The 30-pulse diode rectifier bridge on a 2970-3630 V supply gives you the input harmonics profile a utility or plant distribution engineer expects for a drive this size — no external filter needed for most grid codes. Overload capability: 1.2 In for 60 s standard duty, 1.5 In for 3 s. High-overload profile pushes to 1.5 In for 60 s and 1.85 In for 3 s. That second profile is what you spec for a crusher, centrifuge, or any load that pulls hard on start or jogs.

Physical footprint and construction — this is not a panel-mount drive

Floor-standing enclosure with separate air flows for the transformer and power cells. Dimensions: 2820 mm tall, 3960 mm wide (high efficiency) or 3660 mm wide (standard efficiency), depth 1600 mm (high efficiency) or 1500 mm (standard efficiency). You need a concrete pad and overhead crane access for installation — this isn't a DIN-rail job. The drive ships as a composed assembly: 2 x plinth, phase-shifting transformer, medium-voltage arrestors, cooling fans, HMI, and 15 power cells. Forced convection cooling pulls 29900 m³/h (standard efficiency) or 33200 m³/h (high efficiency) — plan the room ventilation accordingly.

I/O and control supply — what to wire in

Four software-configurable analog inputs (0-20 mA / 4-20 mA, 24 V max, 250 Ohm impedance) and two analog outputs of the same type. Discrete inputs: 6 standard, expandable to 10 optional. The control supply is 220 V AC at 3 kVA external; the cooling fan runs on a separate 380 V AC supply — don't share the control transformer with the fan circuit. Electrical isolation between power and control. Dielectric strength tested at 20 kV AC between earth and power terminals — that's the hipot number the commissioning engineer signs off on.

Standards and compliance — what the CE mark covers

CE marked. Complies with EN/IEC 60204-11 (machinery safety), EN/IEC 60529 (enclosure protection), EN/IEC 61800-3 (EMC for drive systems), EN/IEC 61800-4 (drive performance), and EN/IEC 61800-5-1 (electrical safety). The integrated EMC filter covers conducted emissions for the typical industrial environment. Pollution degree 2 per EN/IEC 61800-5-1, overvoltage category II. Prospective line short-circuit current rated at 31.5 kA for 150 ms — the upstream protection must coordinate with that withstand.

MPN
ATV1200A14305555