Schneider Electric ATV6000C150A1111NA3

Schneider ATV6000C150A1111NA3 ATV6000 Drive, 1500 kVA, 1200

MPN ATV6000C150A1111NA3
Active

Schneider Electric Altivar Process ATV6000, ATV6000C150A1111NA3, medium voltage drive, 1500 kVA, 1200 kW normal duty / 1140 kW heavy duty, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6000C150A1111NA3 specifications
ParameterValue
Input type54 pulse diode rectifier bridge
Current78.8 A normal duty 75 A heavy duty
Frequency50 Hz +/- 5 %
IP ratingIP31
Temp storage max50 °C
Temp storage min0 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature0...50 °C
Pollution degree2 conforming to IEC 61800-5-1
Depth1600 mm
Width4160 mm
Height2751 mm

Product details

The Schneider ATV6000C150A1111NA3 is a medium-voltage variable speed drive from the Altivar Process ATV6000 range, rated for 1500 kVA apparent power and delivering 1200 kW on normal duty or 1140 kW on heavy duty. It drives synchronous, permanent magnet, and asynchronous motors — so it covers the common motor types in a medium-voltage installation without needing a different drive platform.

The 54-pulse diode rectifier bridge keeps input current THDI below 3% per IEEE 519-1992. Line current draws 78.8 A on normal duty and 75 A on heavy duty. Power losses run 52.2 kW normal, 49.6 kW heavy. The drive ships as a complete floor-standing enclosure with power cells, phase-shifting transformer, cooling fans, HMI, medium-voltage arrestors, and plinth — so it arrives as a functional assembly, not a stack of loose modules. The 10-inch LCD touch screen is multi-language, which cuts commissioning time if the crew isn't all English-primary.

Integration notes

Cable entry is bottom only — plan your gland plate and busway accordingly. The enclosure footprint is 4160 mm wide × 1600 mm deep × 2751 mm high; that's a substantial floor area, so confirm the substation or motor control center room can take it before you cut the opening. Noise level is 80 dB — hearing protection zone for anyone near it during operation. Two option-card slots (A and B) accept communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT, plus encoder interfaces (digital, analog, resolver, HTL) and I/O or relay extensions. That covers the common fieldbuses without a gateway box. The control block also has two RJ45 for Ethernet IP/Modbus TCP and one RJ45 for Modbus serial.

MPN
ATV6000C150A1111NA3