Skip to main content
Schneider Electric ATV6A0C40R4

Schneider ATV6A0C40R4 Altivar Process ATV600 Drive, 400 kW

MPN ATV6A0C40R4
Active

Schneider Electric Altivar Process ATV600, modular variable frequency drive, ATV6A0C40R4, 400 kW normal duty at 440 V, STO SIL 3, integrated EMC filter.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6A0C40R4 specifications
ParameterValue
Main product or component typeVariable speed drive
Current623.0 A at 440 V (normal duty) 501.0 A at 440 V (heavy duty)
Frequency50...60 Hz - 5...5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.1 °C
Storage temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Data format8 bits, configurable odd, even or no parity for Modbus serial

Product details

The ATV6A0C40R4: The heavy-duty rating (315 kW / 501 A) is the one you size against for constant-torque loads like conveyors or extruders; the normal-duty figure (400 kW / 623 A) applies for variable-torque pumps and fans. The drive carries STO (Safe Torque Off) to SIL 3, which means it can serve as the safety disconnecting means in a SIL 3 loop without an external safety contactor — a panel-space and wiring savings if your safety architecture requires that integrity level.

This is a current-production drive. No last-time-buy or end-of-life window to manage. The integrated EMC filter meets IEC 61800-3 category C3 with up to 300 m of motor cable, so you can skip an external filter for most installations within that cable length.

Control supply and I/O detail

The control section needs an external 24 V DC supply (19...30 V) for the digital inputs, plus an internal 24 V DC rail (21...27 V) for the STO inputs and general control logic, rated at <200 mA with overload and short-circuit protection. There is also a 10.5 V DC reference output for a 1 to 10 kOhm potentiometer. The six digital inputs (DI1...DI6) are programmable; DI5 and DI6 can serve as pulse inputs up to 30 kHz. Analog inputs AI1, AI2, AI3 are software-configurable for 0...10 V or 0/4...20 mA with 12-bit resolution.

Communication options

Slot A accepts fieldbus option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). Slot A and slot B can also take digital/analog I/O extension or output relay extension modules. The drive ships with a Modbus serial port (2-wire RS 485, RTU frame) and a Modbus TCP/Ethernet port (10/100 Mbit/s, half/full duplex, auto-negotiation).

The drive carries CE marking and is designed to IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic), IEC 60721-3 (environmental), IEC 61508, and IEC 13849-1 (functional safety). Pollution degree 2 per IEC 61800-5-1.

MPN