Skip to main content
Schneider Electric ATV9A0C50N6

ATV9A0C50N6 Altivar Process Drive, 355 kW at 500 V

MPN ATV9A0C50N6
Active

Schneider Electric Altivar Process ATV900, order code ATV9A0C50N6, modular drive, 355 kW at 500 V normal duty, 484 A line current, integrated EMC filter C3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV9A0C50N6 specifications
ParameterValue
Main product or component typeVariable speed drive
Current484.0 A 500 V normal duty) 385.0 A 500 V heavy duty)
Frequency50...60 Hz +/- 5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2

Product details

Drive summary

The ATV9A0C50N6: Switching frequency is adjustable from 2 to 4.9 kHz, but above 2 kHz you'll need to derate current—the datasheet curve is the guide, not the nameplate. Forced convection cooling, so don't skimp on airflow in the panel.

Lifecycle status is listed as current. That means Schneider is still building it, no last-time buy looming. We can quote this drive against an RFQ with standard lead times; no panic to stockpile. Standards compliance covers IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), and functional safety per IEC 61508 and IEC 13849-1. Marking is CE, so it's good for the European market out of the crate.

Integration notes

Cabinet mount only—IP00 behind the door, IP21 or IP54 with the right enclosure. Pollution degree 2, so clean-ish environments preferred. Electrical connections: control uses removable screw terminals 0.5–1.5 mm² (AWG 20–16), line side screw terminal, motor terminals are M10 bars. That's beefy enough for 484 A. For altitude, you can go to 2000 m with no derating; above that, start ratcheting current down per the curve in the manual. Vibration resistance is 0.5 gn at 13–200 Hz, so no special isolation needed for normal plant floors. Potential choices for communication: Slot A accepts Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen (RJ45, SUB-D 9, or screw terminals). Slot B and C can take I/O or relay extension modules. For Modbus serial it's 2-wire RS485 at 4.8–38.4 kbps, with RTU frame and up to 247 addresses. Ethernet ports do 10/100 Mbit/s with half/full duplex and auto-negotiation for IP or Modbus TCP.

MPN
ATV9A0C50N6