Skip to main content
Schneider Electric ATV9A0M12N6

Schneider ATV9A0M12N6 Altivar Process ATV900, 800 kW

MPN ATV9A0M12N6
Active

Schneider Altivar Process ATV900 modular drive, ATV9A0M12N6, 800 kW at 600 V normal duty, heavy duty 710 kW, integrated EMC Category C3 filter, STO SIL3.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV9A0M12N6 specifications
ParameterValue
Main product or component typeVariable speed drive
Current1070.0 A 600 V normal duty) 954.0 A 600 V heavy duty)
Frequency50...60 Hz +/- 5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2
Data format8 bits, configurable odd, even or no parity Modbus serial
Operating temperature23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor

Product details

The ATV9A0M12N6 is an active-production Altivar Process ATV900 drive rated for 800 kW at 600 V normal duty (710 kW heavy duty). It drives synchronous or asynchronous motors and ships as a modular version: control unit, power module, mounting kit, fuses, and front cover. The integrated EMC filter meets Category C3 for cable runs up to 984.3 ft (300 m) — no external filter needed for most industrial installations. That eliminates the external safety relay and simplifies wiring for emergency-stop circuits that need to hold takt time without added latency.

This is a current-production unit (lifecycle stage: current). It carries CE marking and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental conditions), IEC 61508 / IEC 13849-1 (functional safety), and UL 61800-5-1. No last-time-buy or obsolescence watch needed for new designs or spares. Prospective line short-circuit current is rated 50 kA, so the drive handles high-fault-capacity panels without external current-limiting fuses in most distributions.

Integration notes

Cabinet-mount design, IP00 enclosure intended for integration into IP21 or IP54 cabinets. Cooling is forced convection — plan for airflow clearance around the power module. Line-side connection uses M10 screw terminals; motor connections via M10 bars. Control wiring uses removable screw terminals accepting 0.5–1.5 mm² (AWG 20–16). Communication flexibility: on-board Modbus serial RS-485 (2-wire, RTU frame) and Ethernet IP/Modbus TCP at 10/100 Mbit/s. Slot A accepts plug-in modules for Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen (RJ45, SUB-D 9, or screw terminals). Slots A, B, and C also support digital/analog I/O and relay extension modules. Switching frequency is adjustable from 2 to 4.9 kHz with derating factor; fine for pump, fan, conveyor and general motor control. THDI stays below 48 % from 80 to 100 % load.

MPN
ATV9A0M12N6