Skip to main content
Schneider Electric C11E44V050B

Schneider Electric C11E44V050B ComPacT NSXm MCCB, 50 A, 4P,

MPN C11E44V050B
Active

Schneider Electric ComPacT NSXm, C11E44V050B, 4P MCCB, 50 A at 40 °C, 16 kA at 415 V AC, MicroLogic 4.1 electronic trip unit with integrated earth-leakage, grey (RAL 7016).

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C11E44V050B key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm with spreaders 27 mm without spreaders
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

C11E44V050B additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
ColorGrey (RAL 7016)
Depth80 mm
Width108 mm
Height144 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Safety categoryE 16 kA 415 V AC
Operating temperature-25...70 °C

Product details

MCCB for distribution boards — 50 A, 4P, electronic trip with earth-leakage

The Schneider Electric C11E44V050B is a ComPacT NSXm moulded-case circuit breaker (MCCB) rated 50 A at 40 °C with a 4-pole (4P) configuration. The MicroLogic 4.1 electronic trip unit adds integrated earth-leakage protection with selectable sensitivity from 30 mA to 5 A (class A or AC), so it handles both overcurrent and ground-fault detection in a single device — no separate RCCB needed downstream.

The 4P configuration with neutral on the left and front-facing compression-lug/busbar terminals simplifies busbar routing in a standard backplate-mounted panel. The 12-module 9 mm pitch and 108 mm width define the DIN-rail footprint. Integrated earth-leakage protection means this MCCB replaces a separate RCD in the same panel space — the MicroLogic 4.1 trip unit senses both overcurrent and residual current through the same set of conductors. Sensitivity is field-adjustable across 30 mA, 100 mA, 300 mA, 500 mA, 1 A, 3 A, and 5 A for class A or class AC detection. For a distribution board feeding socket outlets or wet-area circuits, 30 mA class A covers personnel protection; 300 mA or higher suits fire-prevention on submain feeders.

IP40 front face and IK07 impact resistance suit enclosed distribution boards. Overvoltage category IV confirms it can be installed at the service entrance or main distribution panel, not just subdistribution.

MPN
C11E44V050B