Skip to main content
Schneider Electric C16B34V100

Schneider Electric C16B34V100 ComPacT NSX 100A Earth Leakage

MPN C16B34V100
Active

Schneider Electric ComPacT NSX, NSX160B frame, 3P, 100 A at 40 °C, MicroLogic 4.2 electronic trip unit, 25 kA Icu at 415 V AC, integrated earth-leakage protection.

$2,083.32 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C16B34V100 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C16B34V100 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In
Mechanical life cycles40000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C16B34V100 is a ComPacT NSX earth leakage circuit breaker on the NSX160B frame, 3-pole, rated 100 A at 40 °C. It carries a MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection — the R function is built in, not an add-on module. Breaking capacity is 25 kA Icu at 380/415 V AC 50/60 Hz per EN/IEC 60947-2, with 40 kA at 220/240 V and 20 kA at 440 V.

The electronic MicroLogic 4.2 provides L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), and R (earth-leakage) protection curves — all four are active simultaneously. The earth-leakage function is integrated, so no external RCD or Vigi module is needed, which saves one slot in the panel. The NSX160B frame accepts plug-in or fixed connections, and the 105 mm width fits standard distribution panel cutouts.

Mounts on a backplate in horizontal or vertical orientation. Front connections on both line and load sides. The 35 mm connection pitch matches standard busbar systems. IP40 front face, IK07 impact rating. The toggle control provides manual ON/OFF switching; the IΔn rotary switch sets the earth-leakage threshold. Five accessory slots are available for auxiliary contacts, shunt trips, or motor mechanisms.

Durability and environment

Mechanical durability is 40,000 cycles. Electrical durability at 440 V In is 20,000 cycles; at 440 V In/2 it reaches 40,000 cycles. Operating altitude is 0–2000 m without derating, 2000–5000 m with derating. Relative humidity range 0–95 %. Thermal memory holds for 20 minutes before and after a trip event, which prevents nuisance reclosing on a hot circuit.

MPN