Skip to main content
Schneider Electric C60H4P6AB

Schneider Electric C60H4P6AB C60H MCB, 4P, 6 A, Curve B, 10

MPN C60H4P6AB
Obsolete

Schneider Electric Multi9 C60H, miniature circuit breaker, 4 poles, 6 A rated current, B curve, 10 kA breaking capacity per EN 60898, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C60H4P6AB specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity10 kA Icn at 230/400 V AC 50/60 Hz conforming to EN 60898 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 125 V DC 2P conforming to IEC 60947-2 30 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 125 V DC 3P conforming to IEC 60947-2 50 kA Icu at 250 V DC 4P conforming to IEC 60947-2
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...70 °C
Depth73 mm
Width72 mm
Height81 mm
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric C60H4P6AB is a 4-pole miniature circuit breaker from the Multi9 C60H series, rated 6 A at 30 °C with a B tripping curve (3–5× In magnetic trip). It breaks 10 kA Icn at 230/400 V AC per EN 60898, and up to 15 kA Icu at 400–415 V AC per IEC 60947-2 — enough for most distribution subfeeds in commercial and light industrial panels. The B curve means the magnetic trip fires between 3 and 5 times the rated current (18–30 A for this 6 A unit), so it's a good fit for resistive or general-purpose loads where inrush stays low — lighting circuits, control transformers, small power supplies. Not the first choice for motor starting unless the motor's locked-rotor current is well under 30 A.

Depth is 73 mm, height 81 mm. Tunnel-type terminals are straightforward for a panel wireman — strip length around 12 mm, no special lug required.

Breaking capacity and service ratings

Under IEC 60947-2 the Icu reaches 15 kA at 400–415 V AC.

MPN
C60H4P6AB