C63W36M500 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch45 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C

All specifications

C63W36M500 additional specifications
ParameterValue
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth110 mm
Width140 mm
Height255 mm
Electrical life cycles8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Mechanical life cycles15000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

The Schneider Electric C63W36M500 is a ComPacT NSX motor-protection circuit breaker with a MicroLogic 6.3 E-M electronic trip unit, rated 500 A at 65 °C and delivering 100 kA Icu at 500 V AC (50/60 Hz) per IEC 60947-2. The E-M trip curve offers L (long-time overload), So (short-time short-circuit), I (instantaneous), and G (ground-fault) protection, with motor tripping classes 5, 10, 20, and 30 selectable. That means you can match the trip class to the motor start profile — a class 10 for a standard pump, class 20 for a high-inertia fan.

The 3-pole design with front connections (upside and downside) simplifies bus-bar or cable routing in a backplate-mounted panel.

The 140 mm width, 255 mm height, and 110 mm depth fit standard MCC bucket cutouts. The LCD display on the MicroLogic 6.3 E-M shows energy metering, demand current, power, phase sequence, and time-stamped event logs — useful for commissioning without a separate power meter. The toggle control and flashing green/red LEDs provide local status at a glance.

Durability and environmental

Rated for 15,000 mechanical cycles and 8,000 electrical cycles at 440 V at half rated current (In/2), or 4,000 cycles at full In. At 690 V, electrical durability is 6,000 cycles at In/2 and 2,000 at In. Operating altitude is 0–2000 m without derating, 2000–5000 m with derating.