Schneider Electric ENW15562

ENW15562 EasyPact NW Trip System 2.0 Control Unit, LI Protec

MPN ENW15562
Active

Schneider Electric EasyPact NW series, Trip System 2.0 control unit, drawout and fixed mounting, LI protection, 630...6300 A, 690 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW15562 specifications
ParameterValue
Trip unit typeMicro-processor based
Main product or component typeControl unit
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Depth77 mm
Width58 mm
Height200 mm
Operating temperature-5...70 °C

Product details

The ENW15562 is a microprocessor-based Trip System 2.0 control unit for the Schneider Electric EasyPact NW range of air circuit breakers. It provides LI protection — overload (long-time) and instantaneous short-circuit — for standard industrial applications on AC networks at 50/60 Hz. The trip unit rating spans 630 to 6300 A, and the long-time pick-up (Ir) is adjustable from 0.4 to 1 x In, with ten settings each for both Ir and the instantaneous pick-up (Ii) range of 1.5 to 10 x Ir. That granularity lets you fine-tune the curve to the load without swapping hardware.

The long-time delay (Tr) is adjustable from 0.5 to 24 s at 6 x Ir, with an accuracy of 0 to -20%. This sets how long the breaker holds during a sustained overload before tripping — critical for coordinating with downstream feeders and avoiding nuisance trips on motor starting inrush. Thermal memory is included, so the trip unit tracks the thermal history of the conductor after a trip. If you reclose quickly, the remaining thermal capacity is accounted for — prevents re-energizing into an already-hot circuit. Fault indication covers overload, short-circuit, and internal fault — three distinct LED states on the front face. That saves panel walk-down time during commissioning or post-fault diagnostics: you see what type of event caused the trip without plugging in a laptop. Mounting mode is drawout and fixed, meaning the same control unit fits both the drawout cradle and the fixed-mount breaker chassis. The neutral position is left, and protected poles can be configured as 3D, 4D, or 3D + N/2 — the neutral protection setting is selectable from off, 0.5 x Ir, or 1 x Ir.

MPN
ENW15562