Schneider Electric ENW15563

ENW15563 EasyPact NW Trip System 5.0, 630-6300 A

MPN ENW15563
Active

Schneider Electric EasyPact NW, Trip System 5.0, control unit, 630-6300 A, 690 V AC, LSI protection, drawout and fixed mounting.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ENW15563 specifications
ParameterValue
Trip unit typeMicro-processor based
Main product or component typeControl unit
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max70 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Depth77 mm
Width58 mm
Height200 mm
Operating temperature-5...70 °C

Product details

The ENW15563 is a microprocessor-based Trip System 5.0 control unit for the Schneider Electric EasyPact NW range of air circuit breakers. It's rated for standard industrial applications on AC networks at 50/60 Hz, with a trip unit rating spanning 630 to 6300 A and a rated operational voltage of 690 V AC conforming to IEC 60947-2. The failure mode this unit addresses is the protection coordination of a large industrial feeder. The LSI protection profile — long-time (L), short-time (S), and instantaneous (I) — means you can shape the trip curve to the load's inrush and the downstream branch's fault-clearing capability. The thermal memory function prevents reclosure into a still-hot conductor, which is the kind of detail that matters when you're coordinating a multi-level distribution system and don't want nuisance trips on a reclose after a transient fault.

Protection curve and adjustability

The long-time pickup (Ir) is adjustable across 10 settings from 0.4 to 1.0 x In, with a corresponding long-time delay (Tr) adjustable from 0.5 to 24 seconds at 6 x Ir, accuracy 0 to -20%. This gives you the granularity to match the thermal curve of a large motor or a transformer-fed load without oversizing the breaker frame. Short-time pickup (Isd) adjusts across 10 settings from 1.5 to 10 x Ir, with a delay (Tsd) from 100 to 600 ms. The instantaneous pickup (Ii) also has 10 settings, ranging from 2 to 15 x In. That range on the instantaneous band — up to 15x In — is what lets you ride through the inrush of a fully loaded transformer bank while still clearing a bolted fault within one cycle.

Physical integration and mounting

The unit measures 200 mm high, 58 mm wide, and 77 mm deep. It mounts via a fixed drawout mechanism — the control unit slides into the breaker cradle without removing the breaker from the switchgear. The neutral position is on the left side of the assembly. Protected poles can be configured as 3D (three poles protected), 3D + N/2 (three poles plus half-rated neutral), or 4D (four poles protected), with neutral protection settings selectable as Without protection, 0.5 x Ir, or 1 x Ir.

MPN
ENW15563