Schneider Electric EVS25H3MW60

Schneider Electric EVS25H3MW60 EasyPact EVS Circuit Breaker,

MPN EVS25H3MW60
Active

Schneider Electric EasyPact EVS, EVS25H3MW60, 3-pole drawout circuit breaker, 2500 A, 65 kA Icu at 440 V AC, IEC 60947-2.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EVS25H3MW60 key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Insulation voltage ui1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Utilization categoryCategory B
IP ratingIP40
Terminal pitch115 mm without spreader
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

EVS25H3MW60 additional specifications
ParameterValue
Temp operating min-5 °C
Pollution degree4 conforming to IEC 60664-1
Depth395 mm
Width441 mm
Height439 mm
Mechanical life cycles20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2
ApplicationDistribution
Operating temperature-5...70 °C

Product details

What the 2500 A and 65 kA ratings mean for your distribution board

The EVS25H3MW60 is a 3-pole drawout air circuit breaker from the Schneider Electric EasyPact EVS range, rated 2500 A continuous at 40 °C with a 65 kA Icu breaking capacity at 220...440 V AC. The 2500 A frame is sized for large distribution transformers or heavy industrial feeders; the drawout design lets you rack the breaker out for maintenance without disturbing the bus connections.

Trip system and protection profile

The EVS Trip System6.0 electronic trip unit provides overload (long-time), instantaneous short-circuit, short-time short-circuit, and earth-fault protection. The 20-minute thermal memory means the trip curve accounts for prior heating — if a motor starts twice in quick succession, the breaker remembers the first start and trips sooner on the second, preventing cumulative overheating of downstream cables. Category B utilisation means the breaker is designed for selectivity with downstream devices: it can hold a short-time delay to let a feeder breaker clear first, then trip itself if the fault persists. The 25 ms maximum break time is fast enough to limit let-through energy.

Mounting and integration into a switchboard

Drawout mounting on a rail base plate with rear vertical or horizontal connections. The 115 mm connection pitch without spreader matches standard bus-bar centres for a 2500 A frame. IP40 protection is typical for indoor switchgear — no special washdown rating, so keep it in a clean, dry enclosure. The 441 mm width, 439 mm height, and 395 mm depth fit standard low-voltage switchgear cubicle compartments.

MPN
EVS25H3MW60