Skip to main content
Schneider Electric EZC250H44250

Schneider Electric EZC250H44250 EasyPact EZC250H 250A 4P Cir

MPN EZC250H44250
Obsolete

Schneider Electric EasyPact EZC250H, 4-pole circuit breaker, 250 A, thermal-magnetic TM-D trip unit, breaking capacity code H, front connections, fixed backplate mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

EZC250H44250 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Insulation voltage ui690 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-35 °C
Temp operating max70 °C

All specifications

EZC250H44250 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-35...85 °C
Pollution degree3 conforming to IEC 60947
Depth60 mm
Width140 mm
Height165 mm
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The EZC250H44250 is a 4-pole thermal-magnetic circuit breaker from the EasyPact EZC250H series, rated 250 A at 40 °C ambient (250 A at 50 °C with the TM-D trip unit). That 250 A continuous rating sets the maximum load current it can carry without tripping — sized for a main feeder or large distribution subfeed in a panel. The H breaking capacity code means it delivers 85 kA Icu at 220–240 V AC and 36 kA at 380–415 V AC, so it can interrupt high fault currents typical of transformer-fed industrial distribution without upstream fuses taking over. At 550 V AC it still holds 10 kA Icu, covering 480 V class systems with headroom. The thermal-magnetic TM-D trip unit provides overload protection (thermal bimetal) and short-circuit protection (magnetic solenoid) in one package — no separate relay or CT needed. Category A utilization means it is not intended for cascaded selectivity with intentional short-time delay; coordination with downstream breakers relies on the instantaneous magnetic trip curve. Suitability for isolation (IEC 60947-2) confirms it can be used as a visible-break disconnector for safe maintenance.

Deployment context

Fixed backplate mount with front connections — the breaker bolts to a panel backplate, and cables land on the front terminals. The 35 mm connection pitch matches standard busbar or cable-lug spacing. Pollution degree 3 (IEC 60947) means it is rated for conductive dust or occasional condensation inside the enclosure — typical of industrial switchrooms.

MPN