Schneider Electric MGN60886

MGN60886 C60N MCB, 2P C-curve 50 A, 20 kA breaking

MPN MGN60886
Obsolete

Schneider Electric C60N Multi9 miniature circuit-breaker, MGN60886, 2-pole, C-curve, 50 A, 20 kA Icu at 240 V AC, thermal-magnetic trip, 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MGN60886 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage440 V AC 50/60 Hz 240 V AC 50/60 Hz phase to phase
Breaking capacity20 kA Icu at 240 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 10 kA Icu at 415 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz phase to phase conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C

All specifications

MGN60886 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
Depth73 mm
Width36 mm
Height81 mm
Electrical life cycles10000 cycles conforming to EN/IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The MGN60886 is a Schneider Electric C60N miniature circuit-breaker from the Multi9 range, rated 50 A at 50 °C per EN/IEC 60947-2 with a C-curve trip characteristic (magnetic threshold 8.5 x In ±20 %). That C-curve means it's the standard choice for general-purpose distribution circuits feeding mixed loads — lighting, small motors, control transformers — where inrush isn't extreme but you still need some headroom above resistive loads. The 20 kA Icu at 240 V AC phase-to-phase tells you it can safely interrupt a fault up to that level without welding contacts or cascading upstream; at 415 V AC that drops to 10 kA Icu, and at 440 V AC to 6 kA Icu, so verify your available fault current at the installation point. The Ics (service breaking capacity) is 75 % of Icu at each voltage level — 15 kA at 240 V AC, 7.5 kA at 415 V AC, 4.5 kA at 440 V AC — meaning after clearing one fault at that level the breaker is still functional, not necessarily still rated for full interruption again.

Snaps onto a 35 mm symmetrical DIN rail, fixed mounting, 2-pole wide (36 mm, 4 x 9 mm pitches). Tunnel-type terminals accept 1.5 to 35 mm² flexible or rigid wire; strip length 14 mm, torque to 3.5 N·m. IP20 finger-safe front. Compatible with comb busbars top or bottom. The separate earth-leakage block (Vigi add-on) clips onto the same footprint if you need residual current protection later.

MPN
MGN60886